1.5.7 Recommended Battery Type
Heavy Duty Batteries to BS3911:982 or IEC95-1
are recommended for all applications.
For temperatures below -18°C (0°F), high discharge,
low resistance Arctic or Alkaline batteries must be
used.
System Volts
Ambient Temperature Range °C (°F)
Above 27° (80°)
26° to 1°
(79° to 34°)
0° to -8°
(32° to -18°)
-9° to -18°
(16° to 0°)
LPW2, LPWS2
12V
115A
150A
210A
350A
24V
75A
90A
140A
215A
LPW3, LPWS3
12V
175A
225A
345A
600A
24V
90A
105A
160A
285A
LPW4, LPWT4, LPWS4, LPWST4
12V
190A
255A
380A
670A
24V
75A
105A
160A
300A
Ambient Temperature Range °C (°F)
30° to 5°
(86° to 41°)
4° to -15°
(39° to 5°)
-16° to -25° (3°
to -13°)
-26° to -32°
(-15° to -26°)
Below -32°
(-26°)
LPW, LPWS
A-D
B-D-F
C-D-I
C-D-I-G
C-D-I-G-H
LPWT4
B-D-F-I
1.15.7.1 Table Code
A. 15W/40 Lubricating oil in the sump.
B. 10W/30 Lubricating oil in the sump.
C. 5W/20 Lubricating oil in the sump.
D. 12 volt starting.
E. Air inlet manifold heater energised while cranking.
F. High discharge, low resistance artic type or alkaline batteries.
G. Heating of the engine and batteries in a housing or engine room.
H. Air inlet manifold heater energised for preheat and while cranking.
1.5.8 Cold Starting Performance
The
figures
given in the table below are for bare
engines only.
Lister Petter Power Systems recommend that a
battery shouldprovide a minimum cranking period
of 60 seconds from a 70% charged 12 volt battery,
with a minimum voltage at the end of the cranking
period of 8.4 volts (16.8 volts on a 24 volt system).