19/48
3.3.
Sound power level
WARNING
Danger of hearing damage
As from a sound power level of 85 dB (A), wearing ear protectors is mandatory.
Where your personal hearing protection.
This specification defines the volume of the noise relative to the operator's workplace and the sound
power level of the floor saw.
The measured sound power level is L
wA
95 dB(A)
The emissions sound pressure at the workplace is L
pA
96 dB(A)
The guaranteed sound power level is:
COMPACTCUT 401 E
96 dB(A)
The values are found by measuring the sound emissions.
The test was performed with a load using the largest permissible saw blade in the floor saw.
Measurement tolerances:
2.5 dB for the evaluated sound power level
4 dB for the evaluated emission sound pressure level
The emissions sound pressure level was determined in accordance with the EN ISO 3744 and EN 13862
standards and EC Directive 2000/14/EC.
3.4.
Hand-arm vibration
WARNING
Danger due to vibration
Vibrations can cause damage to bones or joints and circulation problems.
Take regular breaks when working with the machine
The specified value was determined using the maximum saw blade diameter.
The effects can be inversely proportional to the weight of the operator.
Vibration total value:
COMPACTCUT 401E a
HV
less than 2.5 m/s
2
The following standards were observed during measurement:
EN ISO 5349, VD 2057 Sheet 2, Directive 2002/42/EC.
The specified values were measured while cutting concrete at a cutting depth of 5 cm. In practice, this
value is affected by the following conditions:
-
Quality of the saw blade - Operator’s weight - Aggregate properties
-
Feed speed - Condition of the machine