Operating instructions
4point light 10W (V 4.58)
Auto Settings
Min.Voltage: 10.0 mV
Error U0: 10 %
MaxAv: 128
Fig. 8.10: Auto settings (Auto ON)
Menu item
Function
Min. Voltage:
minimum input voltage for U0 (mV)
Error U0 / U90:
Error of U0
or
U90
MaxAv
Max. Number of averages (1..255)
Tab. 8.14: Auto settings
– e.g. Schlumberger
1. Set minimum input voltage by using the numerical keys
2. Continue with [
] or [
]
3. Set error by using the numerical keys
4. Continue with [
] or [
]
5. Set max. number of averages by using the numerical keys
6. Continue with [
] or [
]
7. Confirm selection with [RET]
You now automatically skip to the data browser and from there to the editable
measurement parameters
➔
Termination criterion can be the error of U0 or U90. Selecting U90 as termination error is useful
for highly accurate automatic IP measurements. Switch from U0 to U90 and v. v. by clicking [
].
8.2.4 Output
After the measurement data are to be transferred to the PC via the serial interface.
Data transmission
is either in
ASCII or binary
format. For transmission in binary format
the program
Com4Point
is necessary.
VES OUTPUT
Single File
All Files
Fig. 8.11: VES output