Rev: 01.07.22
Page 13
CCD-0001459
Fault Code Table - Auto-Programmable Controllers
697096/700156
Flashes
Fault Type Description
Why?
What Should Be Done?
Green
Red
1
1
Minor
Park
brake
not set
(700156
only)
Parking brake (if applicable)
is not set.
Set parking brake (if applicable).
Ground signal is lost at
parking brake receptacle at
control box.
Check for continuity to ground on
wire plugged into parking brake
receptacle at control box.
1
2
Minor
Low
voltage
Incoming voltage to control
is below 12V DC. The room
will not move if the voltage
is 10.5V DC or below.
Start vehicle, generator, or make sure
the unit is plugged in to shore power.
Check 2-pin power connector at
the control box at BATT + and GND.
Consult manufacturer of unit charging
system for troubleshooting assistance.
2
4
Major
Motor 1
fault
Bad wire connection.
Refer to Technical Information Sheets:
Troubleshooting Control Box for
. If necessary,
copy and paste or type the following
path into a browser; https://www.lci1.
com/slide-outs-/support-slimrack then
look for the specified document among
the listing.
Bad motor.
2
2
Major
Motor 2
fault
Bad wire connection.
Bad motor.
1
6
Minor
High
voltage
Supply voltage to control
box is 17V DC or greater.
Consult manufacturer of unit
charging system for troubleshooting
assistance.
1
7
Major
Stops
• Stops have not been set
• Stops were cleared
• Stops were improperly set
Stops need to be programmed
according to the programing
instructions in this document.
1
8
Major
Fuse
Motor fuse concern
Contact Lippert Representative
1
9
Major
Battery
Dropout
Battery dropped below
8.5V while extending or
retracting slides.
Charge battery, start vehicle,
generator, or make sure unit is
plugged into shore power.