Rev: 01.07.22
Page 12
CCD-0001459
Fault Code Table - Auto-Programmable Controllers
1510000236/366701 or 1510000276/366703
Flashes
Fault Type Description
Why?
What Should Be Done?
Green
Red
1
1
Minor
Park
brake
not set
Parking brake (if applicable)
is not set.
Set parking brake (if applicable).
Ground signal is lost at
parking brake receptacle at
control box.
Check for continuity to ground on
wire plugged into parking brake
receptacle at control box.
1
2
Minor
Low
voltage
Incoming voltage to control
is below 12V DC. The room
will not move if the voltage
is 10.5V DC or below.
Start vehicle, generator, or make sure
the unit is plugged in to shore power.
Check 2-pin power connector at
the control box at BATT + and GND.
Consult manufacturer of unit charging
system for troubleshooting assistance.
1
4
Major
Motor 1
fault
Bad wire connection.
Refer to Technical Information
Sheets: Troubleshooting Control Box
for SlimRack Systems
necessary, copy and paste or type the
following path into a browser; https://
www.lci1.com/slide-outs-/support-
slimrack then look for the specified
document among the listing.
Bad motor.
2
4
Major
Motor 2
fault
Bad wire connection.
Bad motor.
1
6
Minor
High
voltage
Supply voltage to control
box is 17V DC or greater.
Consult manufacturer of
unit charging system for
troubleshooting assistance.