6.               

In the event of a malfunction

Malfunction

Possible cause

Remedial action

Lift does not 
function at all

Is the key on the control unit set 
to -I- and are the others set to -0-
or removed?

Set the key switches correctly (see 
4.5 or 4.6)

Is the EMERGENCY STOP 
switch unlocked?

Unlock the EMERGENCY STOP 
switch by turning or pulling 
(depending on the design)

Is the main switch for the lift set 
to -I-?

Turn on the main switch (see 4.1)

Batteries defective or deep 
discharged

Replace the batteries (technical
personnel)

Safety arrester has triggered

Inform technical personnel

Are the safety barriers in the 
horizontal position? 

Actuate the safety barriers again or 
move them slightly up or down

Lift does not 
start when 
platform is 
unfolded and 
occupied

Are the drive-on flaps freely 
movable?

Press the drive-on flaps slightly 
outwards. Drive in the opposite 
direction.

Load-carrying capacity exceeded Reduce weight

Lift does not 
fold 
automatically

Are all key switches at -0-
except at the control station 
selected by you?

Set the key switches correctly (see 
4.5 or 4.6)

In the case of radio-controlled 
control stations: are the batteries 
OK?

Replace the transmitter batteries

If you cannot repair the error yourself in this way, please inform your customer service.

7.

Acoustic warning signals

Duration

[sec.]

Pause

[sec.]

Reason

Remedial action

0.1

5.0

Low battery voltage

(see also 4.2)

Drive to the charging station and 
charge the batteries

0.1

0.5

Acoustic drive warning

     -----

0.1

0.25

Release drive (

see page 4 for 

description

)

     -----

2x briefly

4.0

Overtemperature of 
motor/electronics, or defective 
fuse

It is possible to resume driving after a 
cooling down period of approx. 5 min. 
(If cooling is insufficient, the cooling 
period is extended by a further 5 min.)

3x briefly

4.0

Faulty electronics/motor

Inform customer service

Continuous 
tone

  ----

Emergency call by means of 
beeper on the platform, or 
overloading

Release the emergency call button.
Shift centre of gravity closer to the rail 
or reduce the weight

Note: The acoustic warning signal can be suppressed by pressing the emergency stop button; 
the charging procedure is maintained (exception: continuous tone).

Содержание LL12

Страница 1: ...r 10 4 5 Fetching and sending the platform lift 11 4 5 1 Folding procedure 12 4 6 Travelling with the platform lift 13 4 7 What to do in the event of an unexpected standstill 13 4 7 1 Hand wheel opera...

Страница 2: ...ing additional directives EMC directive 2014 30 EU Low voltage directive 2006 95 EC The following harmonised standards were applied or their protective goals were attained EN 81 40 2009 EN 349 2008 EN...

Страница 3: ...d weight of the platform Load carrying capacity of the platform Serial number Year of manufacture Type designation Type of machine General The rating plate provides the most important information abou...

Страница 4: ...surfaces item 2 green is activated the platform stops moving and an acoustic warning signal is activated After two seconds the platform drives without any command for 1 5 seconds in the opposite dire...

Страница 5: ...ecked and adhered to In Germany a test is obligatory for systems with a lifting height of 3 m In each case proof must be provided and documented in accordance with EN81 40 before the first use The LL1...

Страница 6: ...le and that the permissible loading capacity is not exceeded Loads that protrude beyond the surface area of the opened base may in general not be transported e g large pieces of furniture The LL12 pla...

Страница 7: ...Left hand safety barrier 9 Cover for motor controller front cladding 9 1 Folding seat option 10 Left hand drive on ramp 11 Contact base 12 Lateral drive on ramp option 13 Plug seal 14 charging fuse L...

Страница 8: ...near to the running rail and the platform when the lift is moving Residual danger trapping of loose clothing etc Fold up the lift when not in use Residual danger tripping over Never place your hands...

Страница 9: ...any unnecessary movements on the platform such as rocking or swinging Residual danger falling from the platform Remove dirt from the lift with a little polish or a damp cloth not with a water jet The...

Страница 10: ...ral hours this takes place automatically in the charging station The beep stops after proper charging The sound can be turned off by pressing the emergency stop button this has no influence on the cha...

Страница 11: ...ng renew the batteries at your earliest convenience RED the battery power is very low replace the batteries immediately Fetching and sending the platform lift special version 1 via the external contro...

Страница 12: ...ding procedure is complete If a malfunction should occur during the folding procedure the platform must be folded up or opened manually see below and customer service must be informed The folding proc...

Страница 13: ...for a trip with the platform open via the external control unit This option must be activated by a specialist inside the controller It must be ensured that no third person can suddenly get jump into t...

Страница 14: ...irection of travel should always be towards the lower station less energy expenditure when turning the hand wheel The respective direction of rotation is indicated directly on the hand wheel Note If t...

Страница 15: ...utton p 7 item 3 on the platform Remove the plug seal for the emergency unlocking on the front cladding on the uphill side using a screwdriver or similar Press the lever shown in the picture below rig...

Страница 16: ...hese cases an additional drive on ramp is to be mounted on the long side of the platform p 7 item 12 Folding seat All of our platform lifts can be equipped or retrofitted with a folding seat if desire...

Страница 17: ...e all key switches at 0 except at the control station selected by you Set the key switches correctly see 4 5 or 4 6 In the case of radio controlled control stations are the batteries OK Replace the tr...

Страница 18: ...1 6 01 2017 8 Services performed on your Konstanz stair lift at a glance Installed on Serial no Installed by T V acceptance on No Date Service performed Signature 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Отзывы:

Похожие инструкции для LL12