Operating manual LL12                             11/18                                       Version 1.6        (01/2017)

4.5

Fetching and sending the platform lift

(standard version)

Before each journey, make sure that the acoustic warning signal works. The LL12 
platform lift can be fetched from or sent to another station from any station. To do 
this,  the  key  switch  must  be  inserted  at  the  respective  station,  turned  in  the 
appropriate direction and held in this position.
The  platform  lift  does  not  react  immediately,  but  after  a  delay  time  of  approx.  2 
seconds.

Note:

  The platform lift drives from the external control point only in the folded up 

condition,  i.e.  the  base  of  the  platform  must  be  folded  up  and  the  safety 
barriers folded downwards.

Note:

an LED is mounted on the radio transmitter for fetching/sending the chair lift.

GREEN:     batteries are OK
ORANGE: the  battery  power  is  diminishing;  renew  the  batteries  at  your  earliest 

convenience

   RED:          the battery power is very low; replace the batteries immediately

Fetching and sending the platform lift

(special version 1) [via the external control 

unit, only with 3-position key switch (

p.7, item 2

) for a trip with the platform open 

via the external control unit]. This option must be activated by a specialist inside the 
controller. It  must  be  ensured  that  no  third  person  can  suddenly  get/jump  into  the 
path of the lift.

Condition: driving area is 100% in view !!!!

The key switch (

p.7, item 2

) is to be set to position -II-, otherwise as in 4.5.

Fetching  and  sending  the  platform  lift

(special  version  2)  [via  the  internal 

controller,  only  with  3-position  key  switch  (

p.7,  item  2

)]. This  option  must  be 

activated by a specialist inside the controller.
The platform can be driven via the internal controller in the folded up condition. The 
key switch (

p.7, item 2

) is to be set to position -II- in order to do this. The platform 

lift can now be driven via the internal controller (

p.7, item 1

).

Содержание LL12

Страница 1: ...r 10 4 5 Fetching and sending the platform lift 11 4 5 1 Folding procedure 12 4 6 Travelling with the platform lift 13 4 7 What to do in the event of an unexpected standstill 13 4 7 1 Hand wheel opera...

Страница 2: ...ing additional directives EMC directive 2014 30 EU Low voltage directive 2006 95 EC The following harmonised standards were applied or their protective goals were attained EN 81 40 2009 EN 349 2008 EN...

Страница 3: ...d weight of the platform Load carrying capacity of the platform Serial number Year of manufacture Type designation Type of machine General The rating plate provides the most important information abou...

Страница 4: ...surfaces item 2 green is activated the platform stops moving and an acoustic warning signal is activated After two seconds the platform drives without any command for 1 5 seconds in the opposite dire...

Страница 5: ...ecked and adhered to In Germany a test is obligatory for systems with a lifting height of 3 m In each case proof must be provided and documented in accordance with EN81 40 before the first use The LL1...

Страница 6: ...le and that the permissible loading capacity is not exceeded Loads that protrude beyond the surface area of the opened base may in general not be transported e g large pieces of furniture The LL12 pla...

Страница 7: ...Left hand safety barrier 9 Cover for motor controller front cladding 9 1 Folding seat option 10 Left hand drive on ramp 11 Contact base 12 Lateral drive on ramp option 13 Plug seal 14 charging fuse L...

Страница 8: ...near to the running rail and the platform when the lift is moving Residual danger trapping of loose clothing etc Fold up the lift when not in use Residual danger tripping over Never place your hands...

Страница 9: ...any unnecessary movements on the platform such as rocking or swinging Residual danger falling from the platform Remove dirt from the lift with a little polish or a damp cloth not with a water jet The...

Страница 10: ...ral hours this takes place automatically in the charging station The beep stops after proper charging The sound can be turned off by pressing the emergency stop button this has no influence on the cha...

Страница 11: ...ng renew the batteries at your earliest convenience RED the battery power is very low replace the batteries immediately Fetching and sending the platform lift special version 1 via the external contro...

Страница 12: ...ding procedure is complete If a malfunction should occur during the folding procedure the platform must be folded up or opened manually see below and customer service must be informed The folding proc...

Страница 13: ...for a trip with the platform open via the external control unit This option must be activated by a specialist inside the controller It must be ensured that no third person can suddenly get jump into t...

Страница 14: ...irection of travel should always be towards the lower station less energy expenditure when turning the hand wheel The respective direction of rotation is indicated directly on the hand wheel Note If t...

Страница 15: ...utton p 7 item 3 on the platform Remove the plug seal for the emergency unlocking on the front cladding on the uphill side using a screwdriver or similar Press the lever shown in the picture below rig...

Страница 16: ...hese cases an additional drive on ramp is to be mounted on the long side of the platform p 7 item 12 Folding seat All of our platform lifts can be equipped or retrofitted with a folding seat if desire...

Страница 17: ...e all key switches at 0 except at the control station selected by you Set the key switches correctly see 4 5 or 4 6 In the case of radio controlled control stations are the batteries OK Replace the tr...

Страница 18: ...1 6 01 2017 8 Services performed on your Konstanz stair lift at a glance Installed on Serial no Installed by T V acceptance on No Date Service performed Signature 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Отзывы:

Похожие инструкции для LL12