Instructions
Hydraulic shaker HSA 30
23 - 32
220074-01-EN BA HSA 30 / 28.09.2019
15.3. Shaking unit
Replace shaking unit oil every 200. - Working hours, but at least
1x per year. It is recommended to do it at beginning of the sea-
son.
Shaking unit oil:
Type SAE 90
Volume:
1,5 l.
Shaking unit
– drain of used oil:
•
Drain plug see on lower side of
shaking unit.
Drain / filler plug
Fig. 16
For refilling of shaking unit, tilt shaking head sideward 90°and
fill with oil
– volume see above.
Close drain / filler plug.