Lionel Powered F3 B-Unit Diesel Locomotive Скачать руководство пользователя страница 12

Conventional transformer operations

Operating your locomotive in the conventional environment

Y

our locomotive is capable of operating in the conventional environment with nothing 
more than a standard Lionel alternating-current (AC) transformer. 

In the conventional environment, your locomotive cycles through a repeating pattern of 

operations: forward, neutral, reverse, neutral, and so on. To advance to the next operation, 
press the 

DIRECTION

 button on your transformer. Alternately, you could use the throttle to 

briefly turn off track power so that the locomotive advances to the next operation when power 
is restored.

Once you cycle the locomotive into forward or reverse, you control your locomotive’s 

speed by varying track voltage with the transformer’s throttle. To increase the speed of the 
locomotive, you increase track voltage. To decrease the speed, you decrease track voltage. To 
stop the locomotive and to change directions (or to enter neutral), track voltage is turned off 
or interrupted. 

To experience all of your locomotive’s features, we recommend operating in the LEGACY 

Command Control environment. With a simple one-wire connection, you can use the CAB-2 
Remote Controller to access all of the functions of your locomotive. Refer to pages 5-11 to see 
how to operate your locomotive in the LEGACY Command Control environment.

20

TrainMaster Command Control operations

Reprogramming your locomotive to restore features

I

f your locomotive is unresponsive to your commands in the TrainMaster Command Control 
environment, we recommend that you follow this procedure to reset your locomotive.

1.  Slide the Command reverse unit switch to the PGM position.

2.  Plug in and connect your Command Base.

3.  Place your locomotive on the track, then power up the track.

4. Press 

ENG

 and enter the locomotive’s ID#.

5. Press 

SET

.

6. Press 

ENG

 and enter the locomotive’s ID# again.

7. Press 

AUX1

.

8. Enter 

2

 for this particular locomotive.

9.  Turn off track power and wait ten seconds.

10.  Slide the Command reverse unit switch back to the RUN position.

At this point, your locomotive has been reset. Restore power to the track and operate the 

locomotive as usual. Be sure to use the ID# entered in Step 4.

19

Содержание Powered F3 B-Unit Diesel Locomotive

Страница 1: ...73 4579 250 10 10 Lionel Powered F3 B Unit Diesel Locomotive Owner s Manual Featuring...

Страница 2: ...nel Limited Warranty Policy Service 28 3 Congratulations Congratulations on your purchase of the Lionel powered F3 B unit diesel locomotive On the outside this locomotive features numerous prototypica...

Страница 3: ...transformer or in excess of 19 volts AC may result in damage to sensitive electronic components LEGACY Control operations For the finest operating experience your F 3 B unit locomotive is fully compa...

Страница 4: ...er engines also used to navigate thru info options Set Button Used to set Engine address and for programming Info Button Used to enter view the info options of selected components CTC Button Turns the...

Страница 5: ...dium speed Notice the effect the Train Brake has on sound and speed Try adding more Train brake and notice that the Train Brake can limit the top speed available to your engine Try adding even more Tr...

Страница 6: ...and return to the standard mode and return to the standard control panel 25 Press the speed bar to toggle between the Official RR Speed Control Panel and the Standard Control Panel At this point you k...

Страница 7: ...x 5 Press ADD to add the front engine The engine will move to the right and the blinking box will be ready for your next engine to be added 6 Enter the second engine ID in the blinking box 7 Press ADD...

Страница 8: ...ion or neutral in conventional operation when the switch is placed in the PGM position See pages 17 18 19 and 20 Smoke Unit Switch Used to turn the smoke unit function on and off See page 25 Odyssey I...

Страница 9: ...factory programmed as ID 1 To change the ID see page 17 5 Throttle up and move em out Your locomotive will respond to every command from your CAB 1 Remote Controller 14 Caution TrainMaster Command Con...

Страница 10: ...e rotation Decelerates the locomotive with a counter clockwise rotation Shuts down all PowerMasters on your railroad Stops all TrainMaster Command Control equipped locomotives in operation Use HALT on...

Страница 11: ...itional middle units The back up light and ElectroCoupler will not operate while the unit is in a lash up Address the unit using ENG and its unique ID to access these features Complete the lash up by...

Страница 12: ...ted To experience all of your locomotive s features we recommend operating in the LEGACY Command Control environment With a simple one wire connection you can use the CAB 2 Remote Controller to access...

Страница 13: ...12020 and 6 12054 for FasTrack layouts with the magnetic couplers on the rolling stock Place the trigger disc on the magnetic coupler over the central coil on the Remote Control Track section then pre...

Страница 14: ...eed steps M 100 speed steps and H 100 speed steps with momentum See page 15 Odyssey II Speed Control system operations Odyssey II Speed Control system operations The Odyssey II Speed Control system is...

Страница 15: ...ed smoke unit with variable smoke output In the TrainMaster Command Control environment you may select low medium or high smoke output using your CAB 1 Remote Controller Your locomotive is shipped fro...

Страница 16: ...27 Notes...

Страница 17: ...ges Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specific legal rights and you may ha...

Отзывы: