Installation Guide Linear Motors
ENG
Page 18 / 32
P10-70-SSC / P10-70-SSC-D02
NTI AG / LinMot
Attaching the cable shielding
The power cable is supplied with a copper shielding (see illustration above). This prevents electrical and / or
magnetic fields. The shielded part of the cable must be grounded via a connection to the back wall of the
switchboard. The shielding has to be mounted holohedral to the connection part (see scheme above). The
shield connection terminal block is offered as an accessory for power cables and must be ordered separately
(Item-No. 0150-3631) However, the kind of attaching the cable shielding generally depends on the system of
the switchboard manufacturer.
Connectors
For a complete encapsulation the standard motor connector is welded to the housing of the stator. The
connector is designed for tightening and vertically aligned (see the
section „Stator dimensions“).
Motor connector and cable connector are firmly bolted together. Dimensions and tightening torque are
shown in the following figure.
Q-Connector
8-pin
IP Code: IP69k
Material: Stainless steel, Mat.-No. 1.4404
Max. torque: 0.6 Nm
J-Connector
17-pin
IP Code: IP69k
Material: Stainless steel, Mat.-No. 1.4404
Max. torque: 0.6 Nm
Power Cable
Shrink tubing
Copper shielding
L-Connector (6 pin)
Power Cable
Conductive
mounting plate
Shield connect.
terminal block
Servo Drive