NTI AG / LinMot
User Manual PROFINET PROFIdrive Interface
Page 29/38
3.1.4. Standard telegram 9
Index
Size
[Byte]
Byte
Offset
Name
Data
Type
Tlg 9
10
-
Variables
RECORD
1
2
0
ZSW1
Uint16
2
2
2
AKTSATZ
Uint16
3
2
4
ZSW2
Uint16
4, 5
4
6
XIST_A
Int32
3.1.5. Siemens telegram 105
Index
Size
[Byte]
Byte
Offset
Name
Data
Type
Tlg 105
20
-
Variables
RECORD
1
2
0
ZSW1
Uint16
2, 3
4
2
NIST
Int32
4
2
6
ZSW2
Uint16
5
2
8
MELDEW
Uint16
6
2
10
G1_ZSW
Uint16
7, 8
4
12
G1_XIST_1
Int32
9, 10
4
16
G1_XIST_2
Int32
3.1.6. Siemens telegram TDB 200
Index
Size
[Byte]
Byte
Offset
Name
Data
Type
Tlg TDB
20
-
Variables
RECORD
1
2
0
M_act
Int16
3.1.7. Real Time Config telegram 404
Index
Size
[Byte]
Byte
Offset
Name
Data
Type
Tlg 404
8
-
Variables
RECORD
1
2
0
Config Status Word
Uint16
2
2
2
Config Index/..
Uint16
4, 5
4
4
Config Value
Word32
3.1.8. Actual Position telegram 405
Index
Size
[Byte]
Byte
Offset
Name
Data
Type
Tlg 405
4
-
Variables
RECORD
1, 2
4
0
Actual Position
Int32
3.1.9. Demand Position telegram 406
Index
Size
[Byte]
Byte
Offset
Name
Data
Type
Tlg 406
4
-
Variables
RECORD
1, 2
4
0
Demand Position
Int32
3.1.10. WarnWord telegram 407
Index
Size
Byte
Name