Installation Guide Linear Motors
ENG
NTI AG / LinMot
P01-48-HP EX protected
Page 33 / 47
4.8.1 Determination of the max. possible amount of cont. power dissipation Pv_Max
Example
Motor:
P01-48x360F
T
Water
:
25 °C
➔
Pv
max
= 324 W
•
The coolant temperature must not fall below the ambient temperature, otherwise there
is arisk of condensation.
•
When used and stored in a frost-prone area, corrosion protection (e.g. Clariant) has to
be added.
4.8.2 Determination of water flow Q
Example
Pv:
324 W
ΔT
Water
:
6 °C
➔
Q
Water
= 0.7 l / min
To achieve a very regular cooling of the motor, the max. difference between flow and return
temperature should not exceed 10 ° C.
Содержание 0150-4370
Страница 42: ...Installation Guide Linear Motors ENG Page 42 47 P01 48 HP EX protected NTI AG LinMot ...
Страница 43: ...Installation Guide Linear Motors ENG NTI AG LinMot P01 48 HP EX protected Page 43 47 ...
Страница 44: ...Installation Guide Linear Motors ENG Page 44 47 P01 48 HP EX protected NTI AG LinMot ...
Страница 46: ...Installation Guide Linear Motors ENG Page 46 47 P01 48 HP EX protected NTI AG LinMot ...