Installation Guide Linear Motors
ENG
NTI AG / LinMot
P01-48-HP EX protected
Page 27 / 47
3.11 Cabling
The cables must be laid in such a way that they cannot be damaged by external influences.
4 Installation and commissioning
•
The specified power supply to the drive unit must not be exceeded.
•
All intended operating modes of the linear motors must be designed in accordance with
the design software and verified in application testing.
•
In order to avoid unintended use, the information on the rating plate must be complied
with.
•
Installation must be carried out in accordance with the IEC/EN 60079-14 standard.
4.1 Operating conditions
•
Maximum ambient temperature limits are 0 °C…60 °C
•
The temperature of the cooling fluid must not fall below the ambient temperature, as this
presents a risk of water condensation. See Paragraph 4.8, Liquid cooling.
•
The maximum switch-off temperature to be set on the temperature relay is 85 °C or 135
°C, depending on the temperature class.
•
The max. installation altitude is 2'000 m (for higher values contact LinMot) above sea
level.
•
From 1'000 m, derating of 1 °C per 100 m is to be considered for air cooling.
Temperature relay
Length (Pt1000-cable) = 460 mm
LinMot Servo Drive
Trailing Chain Cable
KS10-EX-Y-Fe/E6k-
EX Linear motor
Содержание 0150-4370
Страница 42: ...Installation Guide Linear Motors ENG Page 42 47 P01 48 HP EX protected NTI AG LinMot ...
Страница 43: ...Installation Guide Linear Motors ENG NTI AG LinMot P01 48 HP EX protected Page 43 47 ...
Страница 44: ...Installation Guide Linear Motors ENG Page 44 47 P01 48 HP EX protected NTI AG LinMot ...
Страница 46: ...Installation Guide Linear Motors ENG Page 46 47 P01 48 HP EX protected NTI AG LinMot ...