Installation Guide Linear Motors
ENG
Page 10 / 47
P01-48-HP EX protected
NTI AG / LinMot
3.1.3 Temperature relay
Receives values from the Pt1000 temperature sensors mounted on the exterior of the motor under the
stainless steel housing. In case of a fault (overtemperature), it initiates the interruption of the power supply to
the servo drive. Feedback to the machine control system.
3.1.4 Circuit breaker
Interrupts the system power supply if the maximum surface temperature setting is exceeded.
3.2 Exterior view
Pt1000 sensors under
stainless steel housing
Copper tubing for
water cooling
Stator with windings (encapsulated)
Water cooling
connection