![background image](http://html1.mh-extra.com/html/linksys/lgs308/lgs308_user-manual_1925095046.webp)
46
For example, if Warning is selected, all severity levels that are Warning and higher are stored in
the log (Emergency, Alert, Critical, Error, and Warning). No events with severity level below
Warning are stored (Notice, Informational, and Debug).
To set global log parameters:
1.
Click
Configuration > System Management > Logs > Log Management
.
2.
Enter the parameters:
•
System Log
o
Logging—Select to enable message logging.
o
Originator Identifier—Enables adding an origin identifier to SYSLOG
messages. The options:
o
None—Do not include the origin identifier in SYSLOG messages.
o
Hostname—Include the system hostname in SYSLOG messages.
o
IPv4 Address—Include the IPv4 address of the sending interface
inSYSLOG messages.
o
IPv6 Address—Include the IPv6 address of the sending interface
inSYSLOG messages.
o
User Defined—Enter a description to be included in SYSLOG messages.
•
Log Settings
o
Severity—Select the severity levels of the messages to be logged to the
following:
o
RAM Memory Logging—Severity levels of the messages to be logged to
the RAM.
o
Flash Memory Logging—Severity levels of the messages to be logged to
the Flash memory.
3.
Click
Apply
. The Running Configuration file is updated.