![Linkcom SlimDoorPhone 1 button Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/linkcom/slimdoorphone-1-button/slimdoorphone-1-button_manual_1923540014.webp)
Linkcom France
11 rue du Soleil Levant 92140 CLAMART
Copyright © 2012 – Linkcom – Tous droits réservés
14
z
– time [sec] after unit goes on hook before dialling [range 1-5]. This time is different for
each PBX, but most PBXs usually manage to process dialling up to 2 seconds after line
on hook.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
56
h
Number of rings before
hanging up or group
mode switching
12
12
12
h
– specifies the amount of time spent ringing before the unit hangs up and tries the next
number.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
57
t
DTMF tone duration
(ms)
5
(100ms)
5
(100m
s)
5
(100m
s)
58
m
Space duration between
DTMF tones (ms)
5
(100ms)
5
(100m
s)
5
(100m
s)
59
f
Recall duration (ms)
1
(100ms)
1
(100m
s)
1
(100m
s)
50
p
Pause duration (ms)
8
(800ms)
8
(800m
s)
8
(800m
s)
t
– DTMF tone duration is determined by the formula:
(entered 5) x 10 = tone duration
[ms]
[range 1-0 i.e. 60-150ms]
m
–
Space duration between DTMF tones
is determined by the formula:
(entered 5) x 10 = gap duration
[ms]
[range 1-0 i.e. 60-150ms]
f
– Recall duration is determined by the formula:
entered number x 100 = Recall duration
[ms]
[range 1-6 i.e. 100-600ms]
p
– Pause duration is determined by the formula:
entered number x 100 = pause duration
[ms]
[range 5-0 i.e. 500-1000ms]
–
p
time is simultaneously the duration of interdigit gap at pulse dialling.
Paramet
er
Value
Description
Default
5*1
x
Number of busy tones before hahg
up
6
x
– is number of busy tones before hahg up by next table:
x
number of busy tones
x
number of busy tones
1
4
5
8
2
4
6
8
3
6
7
10
4
6
8
10
Содержание SlimDoorPhone 1 button