background image

Control

 

Mode

 

 

Controller

 

has

 

inching

 

mode

 

and

 

continued

run

 

mode

 

which

 

is

 

default

 

 

In

 

the

 

continued

run

 

mode,

 

press

 

the

 

up

 

/

 

down

 

key

 

less

 

than

 

1.5

 

seconds,

 

the

 

motor

 

will

 

run

 

continuously,

 

press

 

the

 

up

 

/

 

down

 

key

 

more

 

than

 

1.5

 

seconds,

 

the

 

motor

 

will

 

stop

 

after

 

running

 

160ms

 

 

In

 

the

 

inching

 

mode,

 

press

 

the

 

up

 

/

 

down

 

key

 

less

 

than

 

1.5

 

seconds,

 

the

 

motor

 

will

 

stop

 

after

 

running

 

160ms,

 

press

 

the

 

up

 

/

 

down

 

key

 

more

 

than

 

1.5

 

seconds,

 

the

 

motor

 

will

 

run

 

continuously

 

 

Only

 

the

 

manual

 

buttons

 

on

 

the

 

panel,

 

manual

 

switch,

 

remote

 

control

 

and

 

cascade

 

signal

 

have

 

inching

 

mode

 

 

Keep

 

pressing

 

both

 

of

 

UP

 

and

 

STOP

 

button

 

on

 

the

 

controller

 

for

 

5

 

seconds,

 

L2

 

and

 

L3

 

flash

 

3

 

times

 

and

 

turn

 

off

 

it’s

 

inching

 

mode

 

for

 

the

 

controller,

 

repeat

 

the

 

operation

 

the

 

controller

 

turns

 

to

 

continued

run

 

mode

 

 

Manual

 

control

 

 

After

 

power

 

on

 

all

 

the

 

LEDs

 

light

 

for

 

1

 

second

 

and

 

turn

 

off,

 

the

 

power

 

indicator

 

light

 

L1

 

normally

 

on

   

 

Press

 

K1,

 

all

 

the

 

LEDs

 

light

 

for

 

1

 

second

 

and

 

turn

 

off,

 

reset

 

successfully

 

 

L2

 

will

 

be

 

explosion

flashing

 

after

 

controller

 

receives

 

fire

 

signal

 

 

External

 

manual

 

switch

 

is

 

equivalent

 

to

 

controller

 

panel

 

switch

 

 

The

 

maximum

 

running

 

time

 

of

 

the

 

motor

 

is

 

5

 

minutes

   

 

The

 

motor

 

up

 

/

 

down

 

switching

 

time

 

is

 

500ms

 

Group

 

Control

 

 

By

 

default,

 

L1

 

is

 

normally

 

on,

 

the

 

rest

 

LEDs

 

are

 

off

 

as

 

group

 

control

 

status

 

 

Press

 

K2,

 

L2

 

turns

 

on,

 

the

 

windows

 

open,

 

L2

 

turns

 

off

 

after

 

5

 

seconds

 

 

Press

 

K4,

 

L4

 

turns

 

on,

 

the

 

windows

 

close,

 

L4

 

turns

 

off

 

after

 

5

 

seconds

 

 

Press

 

K3,

 

L3

 

turns

 

on,

 

the

 

motors

 

stop,

 

L3

 

turns

 

off

 

after

 

1

 

second

 

 

Single

 

Channel

 

Control

 

 

Press

 

channel

 

selection

 

keys

 

K5,

 

K6,

 

K7,

 

or

 

K8,

 

the

 

corresponding

 

LED

 

lights,

 

channel

 

selected

 

 

Press

 

the

 

channel

 

selection

 

button

 

again

 

or

 

no

 

operation

 

on

 

K2,

 

K3

 

or

 

K4

 

within

 

10

 

seconds,

 

LED

 

turns

 

off,

 

channel

 

unselected

 

 

In

 

the

 

process

 

of

 

opening/closing

 

the

 

current

 

window,

 

you

 

can

 

select

 

another

 

channel(s)

 

to

 

drive

 

the

 

window

 

 

Remote

 

control

 

 

The

 

controller

 

encodes

 

by

 

433MHz

 

learning

 

code,

 

can

 

store

 

10

 

sets

 

of

 

transmission

 

codes

 

 

The

 

controller

 

defaults

 

to

 

multiple

 

channel,

 

single

 

channel

 

controller

 

has

 

the

 

same

 

way

 

as

 

multiple

 

channel

 

one

 

Matching

 

Code

 

 

Power

 

the

 

controller

 

on,

 

choose

 

the

 

channel(s)

 

you

 

want

 

to

 

set,

 

can

 

be

 

set

 

to

 

any

 

combination

 

of

 

channel

 

1

4

 

 

Keep

 

pressing

 

K3

 

on

 

the

 

controller

 

for

 

5

 

seconds,

 

L3

 

flashes

 

3

 

times

 

and

 

turns

 

off

 

 

Choose

 

the

 

channel

 

you

 

want

 

to

 

set

 

on

 

the

 

remote,

 

press

 

[UP]

 

within

 

15

 

seconds

 

 

LED

 

flashes

 

3

 

times

 

and

 

turns

 

off,

 

code

 

matched

 

successfully

 

Clearing

 

Single

 

Code

 

 

Power

 

the

 

controller

 

on

 

 

Keep

 

pressing

 

K3

 

on

 

the

 

controller

 

for

 

5

 

seconds,

 

L3

 

flashes

 

3

 

times

 

and

 

turns

 

off

 

 

Press

 

[DOWN]

 

on

 

the

 

remote

 

within

 

15

 

seconds

 

 

LED

 

flashes

 

3

 

times

 

and

 

turns

 

off,

 

code

 

cleared

 

successfully

 

Clearing

 

All

 

Codes

 

 

Power

 

the

 

controller

 

on,

 

keep

 

pressing

 

K3

 

&K4

 

on

 

the

 

controller

 

for

 

5

 

seconds

 

 

L3

 

and

 

L4

 

flash

 

3

 

times

 

and

 

turn

 

off

 

 

All

 

the

 

codes

 

will

 

be

 

deleted

 

after

 

this

 

operation

 

Содержание LK-CP7 Series

Страница 1: ...unction External power supply 35W 72W 150W 300W Model List Model Control Method Input Volt V Output Volt V Freq MHz Temp Size mm LK CP711 1 way single LK CP722 2 way single group LK CP721S 2 way sync...

Страница 2: ...On Off AC power indicator Reset L2 K2 Green On Off Flash Open L3 K3 Red On Off Flash Stop L4 K4 Yellow On Off Flash Close L5 K5 Blue On Off Flash Channel 1 L6 K6 Blue On Off Flash Channel 2 L7 K7 Blu...

Страница 3: ...e M4 M4 Positive Motor M4 M4 Negative M M is also cascade output connecting with S S 24V DC24V 12V DC12V DC Output GND DC GND MU Manual Open 1 MS Manual Stop 1 MD Manual Close 1 MG Manual Switch GND S...

Страница 4: ...the windows open L2 turns off after 5 seconds Press K4 L4 turns on the windows close L4 turns off after 5 seconds Press K3 L3 turns on the motors stop L3 turns off after 1 second Single Channel Contro...

Страница 5: ...tor the controller immediately shields all the input signals the controller must be reset by pressing K1 manually After wired W R sensor signal processed the controller shields lower priority signal o...

Страница 6: ...he default is all selected all the channel indicators light Press the channel selection key S the indicators light press the channel selection key S again the indicator is off it is deselected The set...

Страница 7: ...1 5 meters The distance between the controller and the ceiling should be greater than 0 3 meters The distance between the controller and the motor should be greater than 1 5 meters Avoid static interf...