background image

Signal

 

Control

 

 

Manual

 

signal.

 

Control

 

the

 

window

 

by

 

the

 

buttons

 

on

 

itself,

 

external

 

dry

 

contact

 

manual

 

switch

 

and

 

RF

 

remote

 

 

Cascaded

 

signal.

 

As

 

a

 

master

 

controller

 

sends

 

signal

 

to

 

the

 

slave

 

controller,

 

can

 

also

 

be

 

used

 

as

 

slave

 

controller

 

to

 

receive

 

the

 

signal

 

from

 

the

 

master

 

controller

 

to

 

drive

 

the

 

window

 

 

Fire

 

signal.

 

Capable

 

of

 

receiving

 

a

 

signal

 

from

 

fire

 

center,

 

smoke

 

sensor,

 

gas

 

detector

 

open

 

the

 

window

 

automatically

 

 

Wind/Rain

 

signal.

 

After

 

receiving

 

the

 

signal

 

of

 

wind/rain

 

sensor

 

close

 

the

 

window

   

 

Temperature/humidity

 

signal.

 

Control

 

the

 

window

 

by

 

processing

 

external

 

temperature/humidity

 

sensor

   

 

Time

 

signal.

 

Control

 

the

 

window

 

by

 

working

 

with

 

external

 

timer

 

 

Signal

 

and

 

Priority

 

Signal

 

Manual

 

Signal

Fire

 

Signal

 

W/R

 

Signal

Time

 

Signal

T/H

 

Signal

 

Priority

 

1

 

2

 

3

 

4

 

5

 

 

Manual

 

signal

 

includes

 

the

 

signal

 

from

 

buttons

 

on

 

the

 

controller,

 

external

 

dry

 

contact

 

manual

 

switch,

 

wall

 

transmitter,

 

hand

 

held

 

remote,

 

wireless

 

W/R

 

sensor,

 

wireless

 

timer

 

and

 

cascaded

 

signal

 

 

Fire

 

signal

 

includes

 

the

 

signal

 

from

 

fire

 

centre,

 

smoke

 

sensor

 

and

 

gas

 

detector

 

 

W/R

 

signal

 

includes

 

the

 

signal

 

from

 

wired

 

wind

 

and

 

rain

 

sensor,

 

NOT

 

including

 

wireless

 

W/R

 

sensor

 

 

Time

 

signal

 

is

 

only

 

the

 

signal

 

from

 

WIRED

 

timer

   

 

T/H

 

signal

 

includes

 

the

 

signal

 

from

 

temperature

 

or

 

humidity

 

sensor

 

 

Reset

 

and

 

Shielding

 

 

After

 

manual

 

signal

 

processed

 

controller

 

resets

 

&

 

receives

 

input

 

signal

 

in

 

real

 

time

   

 

After

 

processing

 

the

 

signal

 

from

 

fire

 

centre,

 

smoke

 

sensor

 

or

 

gas

 

detector,

 

the

 

controller

 

immediately

 

shields

 

all

 

the

 

input

 

signals,

 

the

 

controller

 

must

 

be

 

reset

 

by

 

pressing

 

K1

 

manually.

   

 

After

 

wired

 

W/R

 

sensor

 

signal

 

processed,

 

the

 

controller

 

shields

 

lower

 

priority

 

signal,

 

only

 

receives

 

the

 

higher

 

priority

 

signal

 

until

 

reset

 

or

 

manual

 

signal

 

processed

 

 

After

 

wired

 

timer

 

signal

 

processed,

 

the

 

controller

 

shields

 

lower

 

priority

 

signal,

 

only

 

receives

 

the

 

higher

 

priority

 

signal

 

until

 

reset

 

or

 

manual

 

signal

 

processed

   

 

After

 

T&H

 

sensor

 

signal

 

processed

the

 

controller

 

is

 

in

 

the

 

reset

 

state

 

 

Option

 

switch

 

on

 

the

 

control

 

board

 

is

 

for

 

selection

 

of

 

shielding

 

priority

 

3

5

 

signal

 

Option

 

1

3

 

priorities

 

3

5

 

respectively.

 

The

 

setting

 

takes

 

effect

 

after

 

reset

 

or

 

restart

 

 

Switch

 

Option

 

Function

 

Y

 

Wind/Rain

 

sensor

 

shielded

 

Option1

 

N

 

Not

 

shield

 

Wind/Rain

 

sensor

 

Y

 

T&H

 

sensor

 

shielded

 

Option2

 

N

 

Not

 

shield

 

T&H

 

sensor

 

Y

 

Timer

 

shielded

 

Option3

 

N

 

Not

 

shield

 

Timer

 

 

Cascaded

 

Control

 

 

LK

CP711

 

/

 

722

 

/

 

744

 

can

 

be

 

used

 

as

 

a

 

master

 

controller,

 

a

 

slave

 

controller

 

or

 

play

 

a

 

dual

 

role

 

of

 

master

 

&

 

slave

 

controller

 

at

 

the

 

same

 

time.

   

 

LK

CP721S

 

/

 

731S

 

/

 

741S

 

/742S

 

can

 

only

 

be

 

a

 

slave

 

controller

 

 

As

 

a

 

master

 

controller,

 

connects

 

to

 

the

 

motors

 

or

 

slave

 

controllers

 

to

 

drive

 

them

 

 

As

 

a

 

slave

 

controller,

 

input

 

terminals

 

S+

 

and

 

S

‐ 

are

 

connected

 

to

 

the

 

output

 

terminals

 

M+

 

and

 

M

‐ 

of

 

the

 

master

 

controller

 

to

 

receive

 

the

 

instructions

 

to

 

drive

 

motors,

 

or

 

drive

 

the

 

motors

 

independently

 

 

Play

 

a

 

dual

 

role

 

of

 

master

 

&

 

slave

 

controller,

 

not

 

only

 

controlled

 

by

 

higher

level

 

controller,

 

but

 

also

 

drive

 

motors

 

or

 

lower

level

 

controllers

 

independently

   

 

No

 

matter

 

master,

 

slave

 

or

 

both,

 

it

 

can

 

process

 

all

 

the

 

external

 

signals

 

such

 

as

 

manual

 

switch,

 

remote

 

and

 

sensors

 

 

Содержание LK-CP7 Series

Страница 1: ...unction External power supply 35W 72W 150W 300W Model List Model Control Method Input Volt V Output Volt V Freq MHz Temp Size mm LK CP711 1 way single LK CP722 2 way single group LK CP721S 2 way sync...

Страница 2: ...On Off AC power indicator Reset L2 K2 Green On Off Flash Open L3 K3 Red On Off Flash Stop L4 K4 Yellow On Off Flash Close L5 K5 Blue On Off Flash Channel 1 L6 K6 Blue On Off Flash Channel 2 L7 K7 Blu...

Страница 3: ...e M4 M4 Positive Motor M4 M4 Negative M M is also cascade output connecting with S S 24V DC24V 12V DC12V DC Output GND DC GND MU Manual Open 1 MS Manual Stop 1 MD Manual Close 1 MG Manual Switch GND S...

Страница 4: ...the windows open L2 turns off after 5 seconds Press K4 L4 turns on the windows close L4 turns off after 5 seconds Press K3 L3 turns on the motors stop L3 turns off after 1 second Single Channel Contro...

Страница 5: ...tor the controller immediately shields all the input signals the controller must be reset by pressing K1 manually After wired W R sensor signal processed the controller shields lower priority signal o...

Страница 6: ...he default is all selected all the channel indicators light Press the channel selection key S the indicators light press the channel selection key S again the indicator is off it is deselected The set...

Страница 7: ...1 5 meters The distance between the controller and the ceiling should be greater than 0 3 meters The distance between the controller and the motor should be greater than 1 5 meters Avoid static interf...

Отзывы: