Panel

 

Description

 

LED

 

/

 

KEY

 

Color

 

Status

 

Function

 

L1

 

/

 

K1

 

Blue

 

On

 

/

 

Off

 

AC

 

power

 

indicator,

 

Reset

L2

 

/

 

K2

 

Green

 

On

 

/

 

Off

 

/

 

Flash

 

Open

 

L3

 

/

 

K3

 

Red

 

On

 

/

 

Off

 

/

 

Flash

 

Stop

 

L4

 

/

 

K4

 

Yellow

 

On

 

/

 

Off

 

/

 

Flash

 

Close

 

L5

 

/

 

K5

 

Blue

 

On

 

/

 

Off

 

/

 

Flash

 

Channel

 

1

 

L6

 

/

 

K6

 

Blue

 

On

 

/

 

Off

 

/

 

Flash

 

Channel

 

2

 

L7

 

/

 

K7

 

Blue

 

On

 

/

 

Off

 

/

 

Flash

 

Channel

 

3

 

L8

 

/

 

K8

 

Blue

 

On

 

/

 

Off

 

/

 

Flash

 

Channel

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

 

 

Содержание LK-CP7 Series

Страница 1: ...unction External power supply 35W 72W 150W 300W Model List Model Control Method Input Volt V Output Volt V Freq MHz Temp Size mm LK CP711 1 way single LK CP722 2 way single group LK CP721S 2 way sync...

Страница 2: ...On Off AC power indicator Reset L2 K2 Green On Off Flash Open L3 K3 Red On Off Flash Stop L4 K4 Yellow On Off Flash Close L5 K5 Blue On Off Flash Channel 1 L6 K6 Blue On Off Flash Channel 2 L7 K7 Blu...

Страница 3: ...e M4 M4 Positive Motor M4 M4 Negative M M is also cascade output connecting with S S 24V DC24V 12V DC12V DC Output GND DC GND MU Manual Open 1 MS Manual Stop 1 MD Manual Close 1 MG Manual Switch GND S...

Страница 4: ...the windows open L2 turns off after 5 seconds Press K4 L4 turns on the windows close L4 turns off after 5 seconds Press K3 L3 turns on the motors stop L3 turns off after 1 second Single Channel Contro...

Страница 5: ...tor the controller immediately shields all the input signals the controller must be reset by pressing K1 manually After wired W R sensor signal processed the controller shields lower priority signal o...

Страница 6: ...he default is all selected all the channel indicators light Press the channel selection key S the indicators light press the channel selection key S again the indicator is off it is deselected The set...

Страница 7: ...1 5 meters The distance between the controller and the ceiling should be greater than 0 3 meters The distance between the controller and the motor should be greater than 1 5 meters Avoid static interf...