Before Setting Up Your Equipment 

 

Please  register  your  products  by  going  to 

www.linkam.co.uk

  and  click  on  the 

product/software registration button.

 

 

You will need to register your equipment with us to:

 

 

 

 Activate your warranty and technical support

 

 

 Access the online setup videos

 

 

 Permanently unlock the Linksys32 software (if purchased)

 

 

If you have purchased Linksys32 software, please install the software first.

 

 This pro-

cess will guide to register all of your products.

 

 

See Linksys32 manual for further installation instructions.

 

 

A CD with a setup videos is supplied with your system.

 

Содержание LTS120

Страница 1: ...LTS120 Temperature Controlled Stage Linkam Scientific Instruments USER GUIDE...

Страница 2: ...ovetail Substage 9 Setting up the Condenser 9 Setting up ECP Water Circulator Pump 10 Connecting the Instruments 11 T95 System Controller Cable Connections 11 Sample preparation 12 Loading a Sample 12...

Страница 3: ...with us to Activate your warranty and technical support Access the online setup videos Permanently unlock the Linksys32 software if purchased If you have purchased Linksys32 software please install t...

Страница 4: ...r this product must be returned to Linkam or a designated service facility The warranty shall not apply to defects resulting from interfacing unauthorized modification or misuse operation outside of t...

Страница 5: ...Support 8 The equipment is not intended to be used outdoors 9 Each product is equipped with a 3 wire grounded earth mains plug or a free end 3 wire mains lead The plug only fits into a grounded type o...

Страница 6: ...denser lens WD 13 2mm XY Manipulators travel 15mm Aperture hole 2 5mm LTS120 System The system consists of a LTS120 stage T95 Linksys32 System Controller Linksys32 with digital video capture can be ad...

Страница 7: ...notches 3 on the XY Manipulator Assembly and place the holder in place Use the screw 2 to fix the Microscope Slide Holder in place Note when fitted properly the Microscope Slide Holder should not touc...

Страница 8: ...r Cooling Connector for Peltier element 8 Metal Plate Cover 9 Aperture hole 2 5mm 10 Stage Chamber 11 Peltier Heating cooling block 40x40mm 12 Y manipulator 13 X manipulator 14 Rubber sealing o ring 1...

Страница 9: ...ing screws 2 ensure that the aperture is in the centre of the field of view and lock the stage in place by tightening the Locking Thumbscrew 3 For other types of microscope substage refer to the diagr...

Страница 10: ...ature gradient needed to make the Peltier heat and cool The ECP must be connected to the LTS120 See the ECP manual for instruction setting up the ECP Connect the tubing to the Inlet and Outlet as show...

Страница 11: ...ystem Controller Cable Connections For more details on the T95 System Controller please refer to the T95 System Controller manual Connect the Stage Cable Connector from the LTS120 stage to the Stage C...

Страница 12: ...croscope Slide Holder use a spatula and tap on the microscope glass slide to make sure that it is sitting flat on the heating block Place the sample on top of the microscope glass slide Ensure that th...

Страница 13: ...use the LinkPad touch screen or Linksys32 software to heat the stage to 40 C 3 From a gas cylinder connect the Gas Insert with a tubing 3mm inner diameter and 6mm outer diameter to the Gas Purge Valve...

Страница 14: ...flow rate of 20cc min and thread it through the Tube Clip Holder 1 Place in position as seen the the opposite picture This tube blows warm gas across the lid window to prevent condensation on the view...

Страница 15: ...s supplied with internal electrical contacts for LTSE120 or Liquid Crystal Stage LTSE120 Stage with Internal Electrical Contacts The stage is supplied with two internal electrical contact connectors 1...

Страница 16: ...Contact The internal electrical contact has a self closing spring loaded pin 1 Using a finger tip push in the pin to open the electrical contact and insert a wire into the contact 2 Release the finge...

Страница 17: ...ug by holding it firmly and pull it gently away from the Stage Wire up the Lemo to your instrument To reconnect the Lemo line up the red dot on the Lemo plug 1 to the red dot on the Lemo socket 2 and...

Страница 18: ...al Holder 1 to the XY Assembly as shown on page 6 Note make sure the Liquid Cell Holder is the right way up as shown in the opposite picture Connect the two wires from the Liquid Cell Hold er to the I...

Страница 19: ...and reassembled in the order indicated The Lid Insert should be screwed down until the cover slips are held firmly then turn the assembly over and screw down the Lid Insert until it is felt to come t...

Страница 20: ...ert x2 WVC Water Gas Valve Connector x2 SSR Silicon Rings for Lid and Base Set of 4 WT Window Tool for unlocking lid insert and base locking ring TCH Tube Clip Holder for Nitrogen de fogging stage lid...

Страница 21: ...ature sen sor is brittle and can be broken if cleaning is not carefully performed We recommend a spare heating element to avoid downtime with your stage while element is being repaired Part No Part Na...

Страница 22: ...22 This page is intentionally Blank...

Страница 23: ...23 This page is intentionally Blank...

Страница 24: ...ruments Ltd Tel 44 0 1737 363 476 Fx 44 0 1737 363 480 info linkam co uk Unit 8 Epsom Downs Metro Centre Tadworth Surrey KT20 5LR UK www linkam co uk Ver 1 1 1209 Powered by TCPDF www tcpdf org Powere...

Отзывы: