Move the bed on even, hard-surfaced floors only.
Replace any damaged parts immediately with original spare parts only.
Ensure that maintenance and installation are performed only by qualified personnel who have been
trained by the manufacturer.
Do not apply excess weight or loads to the bed according to SWL.
During peak loads or unavoidable excess loads (CPR), place mattress platform in the lowest position.
Ensure that only one patient uses the bed at any time.
Take care to avoid injuries or squeezing when operating moving parts.
When using lifting poles or infusion stands, ensure that nothing will be damaged when you move or adjust
the bed.
Brake the castors when the bed is occupied.
Keep the mattress platform in the lowest position at any time when the healthcare personnel is not treating
the patient in order to prevent the patient from falling or injuries.
Ensure that siderails are operated by healthcare personnel only.
Never use the bed in areas where there is a hazard of explosion.
Enable or disable functions on the handset using the supervisor panel as appropriate for the
patient’s
physical and mental state. Verify that the function is actually disabled.
Never handle the mains plug with wet hands.
Remove the mains cable by pulling on the plug only.
Position the mains cable so that there are no loops or bends in the cable; protect the cable from
mechanical wear and tear.
Improper handling of mains cable can cause an electric shock hazard, other serious injuries or damage
the bed.
Ensure that the stipulated duty cycle (on-time) is not exceeded.
Ensure that the moving parts of the bed are not blocked.
To prevent failures, use
the manufacturer’s original accessories and mattresses only.
Ensure that the stipulated safe working load is not exceeded.
If the patient's condition could lead to an entrapment, leave the mattress support platform in the flat
position whilst unattended.
Close linen shelf before using the Reverse Trendelenburg position.
Always set mattress platform to its lowest position and single parts of mattress platform to horizontal
position in case the patient is left on the bed without supervision of personnel and if his health and mental
status may indicate increase risk of falling out of the bed or entrapment.
Personnel must consider overall adjustment of the bed and locking all of the positioning functions in
accordance to health and mental status of patient, especially if the patient is left without supervision (even
for short period of time) of the personnel.
Manual positioning of parts of the bed which are designed for electronic positioning (e.g. back rest) is
forbidden. Otherwise there is a risk of damaging and dysfunction of the back rest actuator or unprompted
fall of the back rest.