background image

 
 
 
 

TOTAL STATION

 

 
 

LTS-200

SERIES

 

 
 

 

LTS-202N 
LTS-205N 

 
 
 
 

I

NSTRUCTION MANUAL 

Basic Procedures

 

 
 
 
 
 

 
 

Содержание LTS-200 Series

Страница 1: ...TOTAL STATION LTS 200SERIES LTS 202N LTS 205N INSTRUCTION MANUAL Basic Procedures...

Страница 2: ......

Страница 3: ......

Страница 4: ...ighting 24 3 7 Attachment and detachment of tribrach 25 4 TURNING THE POWER ON 26 4 1 Turning the power on and off 26 4 2 Adjusting LCD contrast 26 4 3 Adjusting illumination brightness 27 4 4 Adjusti...

Страница 5: ...al reticle 53 11 4 Perpendicularity of line of sight to horizontal axis 54 11 5 Vertical 0 point error 55 11 6 Laser plummet 55 11 7 Offset constant 56 11 8 Beam axis and line of sight 57 11 9 The EDM...

Страница 6: ...eration incurred by the use of this product or malfunction of it 3 TIA shall not be liable for damage caused by usage not explained in the instruction manual 4 TIA shall not be liable for damage to th...

Страница 7: ...hich treatment will not likely require hospitalization or long term attention Material damage refers to damage to facilities buildings acquired data etc Before using this product be sure that you have...

Страница 8: ...event making short circuit when removing the battery and charger from the case and storing them apply electrically resistant tape to the poles of the battery Storing the battery and charger as it is m...

Страница 9: ...njury Make sure the tripod itself and the instrument on the tripod are both installed securely as insecure installation may cause the tripod to fall over or the instrument to drop resulting in possibl...

Страница 10: ...sight axis but both axes may deviate slightly because of intense temperature changes and a long time lapse Target constant Confirm the Target Constant of the instrument before measurement If a differe...

Страница 11: ...f damaging the instrument If water should happen to splash on the instrument or the battery wipe it off immediately and allow it to dry in a dry location Do not put the instrument in the case until it...

Страница 12: ...instrument is to be stored for an extended period of time The instrument should also be removed from its case occasionally and aired out In addition to these precautions be sure to handle the instrume...

Страница 13: ...mark Battery latch Battery pack Telescope tangent screw Telescope clamp screw Clamp screw Tangent screw Base plate Top handle Collimator Eyepiece ring Eyepiece Laser indicator Plate vial SD USB cover...

Страница 14: ...attery 2 pcs BC04 Charger AC Adapter Power supply cord Plumb bob Plummet hook Hexagonal wrench Adjusting pin Screwdriver Rain cover CD ROM Basic operation Special Functions manual USB cable RS232 cabl...

Страница 15: ...case Packing the instrument in the case Make sure the telescope is fairly levelled and lightly tighten the telescope clamp screw Line up the housing marks round yellow marks on the instrument and tig...

Страница 16: ...operating time between 8 EDM ETH to 22hours ETH only Specifications Battery Type Li ion Voltage 7 4VDC Capacity 4400mAh Battery Charger AC Adapter Input 100 240VAC 50 60Hz 0 58A Output 12 0VDC 2 0A Ch...

Страница 17: ...SB cover Insert the SD card The side with terminal should face the instrument and the cut off corner should be up Insert the SD card to the end Be sure not to press the card too hard After the SD card...

Страница 18: ...whether other brand SD cards not mentioned here can be used with the LTS 200 series Total Station Please note that the test has been done by us and it is not meant that each SD card manufacturer guara...

Страница 19: ...d screen value LASER Displays the laser plummet and the LD point screen when you push the Laser key Refer to 2 5 LD POINT Laser pointer 3 2 Laser plummet Alphanumeric At the numerical value screen the...

Страница 20: ...pressing twice S FUNC F4 LinertecExpress Special Functions MODE F5 Switches the screen between MODE A and MODE B MODE B DISP F1 Switches the display composition in the order H angle H dst V dst H ang...

Страница 21: ...creen RETICLE F3 Changing the reticle illumination when pressing illumination key LCD F4 Changing the LCD contrast when pressing illumination key ILLU F5 Changing the LCD illumination when pressing il...

Страница 22: ...on is turned on The Laser indicator is turned on and the mark on the left of the screen blinks while the Laser pointer function is operating If the Laser key is pressed and the F2 RED MARK key is pres...

Страница 23: ...ction of fixing the metal shoes into the ground correct the level by extending or retracting each leg of the tripod 3 2 Laser plummet Laser plummet model The instrument is equipped with the laser plum...

Страница 24: ...tness of the laser if necessary If Laser F4 PLUM ADJ are pressed in due course the brightness adjustment screen of the laser plummet device is displayed The Laser plummet becomes darker or brighter by...

Страница 25: ...ion of the tripod points do not change 3 4 Levelling with the plate vial A Align the plate vial in parallel with a line joining any two of the levelling screws Then adjust the two screws to centre the...

Страница 26: ...e eyepiece and rotate the eyepiece ring clockwise until the reticle appears at its maximum sharpness When looking into the eyepiece avoid an intense look to prevent parallax and eye fatigue When it is...

Страница 27: ...e the Focus ring and stop it where the target can be clearly seen and the target image does not move in relation to reticle even if your eye is vertically and horizontally moved Align the reticle accu...

Страница 28: ...ntil the arrow points upward and lift the instrument up Attachment Mount the instrument on the tribrach with the guide marks coinciding and rotate the locking knob until the arrow points downwards The...

Страница 29: ...umination key to access the screen for adjusting LCD contrast Pressing the F1 will lighten the contrast while pressing the F2 will darken the contrast Press ENT to exit adjustment mode and return to t...

Страница 30: ...the Illumination key views the F3 RETICLE F4 LCD and F5 ILLU Illumination brightness of the LCD screen and telescope reticle may be adjusted as necessary at any time Illumination brightness may be ad...

Страница 31: ...F5 MODE and F4 DISP key cycles through the sets of display items H angle H dst V dst H angle V angle S dst and H angle V angle H dst S dst V dst Even though you turn the power off during a survey the...

Страница 32: ...e in succession The horizontal angle value is displayed in reverse video when being held Pressing F5 MODE and press F3 HOLD The F3 HOLD cannot hold the vertical angle or distance To release the horizo...

Страница 33: ...numeric key as 123 4520 Press the ENT key to accept the horizontal angle set to 123 45 20 and change the screen The former data is called by pressing the CLEAR key again 5 5 Displaying the slope of t...

Страница 34: ...range message to the numeric value 5 6 Changing the horizontal angle from clockwise to counter clockwise Press F5 MODE Press F2 ANG SET to display the ANGLE SET screen Press F4 to move the cursor to 3...

Страница 35: ...ry when the target does not satisfy the conditions above at survey work Pay attention to the following in case of distance measurement by Reflectorless In case of resulting in low accuracy perform the...

Страница 36: ...ce goes to second MEAS You can freely select and allocate your desired measurement mode in primary MEAS and second MEAS by the initial setting 2 The MEASURE SHOT is set at primary MEAS and TRACK CONT...

Страница 37: ...e the telescope at a Target and press F1 MEAS twice to start measuring the distance Upon reception of a reflected light from the target the instrument beeps and displays the mark to start the TRACK di...

Страница 38: ...ing 1 Example Prism Constant 25mm setting Press F4 CORR in MODE B If the instrument is in MODE A press F5 MODE to enter MODE B Press the F5 SELECT to enable the Prism Constant to be changed Clear the...

Страница 39: ...nt remain on the measurement screen as S 0 or P 0 The factory initial of Reflector sheet Constant and Prism Constant are 0 Once set each Constant remains in memory even after the power is turned off 7...

Страница 40: ...rection is based on 15 C If this instrument is used without correcting the temperature a distance error per 100m is about 0 1mm per 1 C as a temperature difference from 15 C A distance error per 100m...

Страница 41: ...13hPa Once set the pressure remains in memory even after the power is turned off Pressure correction is based on 1013 hectopascals hPa If this instrument is used without correcting the pressure a dist...

Страница 42: ...the instrument to MODE A The valid range of ppm values is from 199 to 199 Once set the ppm value is displayed at the centre of the top of the measurement screen The factory initial of ppm value is 0...

Страница 43: ...f these conditions is marked by To change initial setting follow the operating procedures for entering each initial setting mode in 8 2 and the operating procedures for changing an initial setting in...

Страница 44: ...ntering the mode for initial setting 4 Press the POWER key while holding F4 key down to access the screen for initial setting 4 Select the item of interest in the same way as in the mode for initial s...

Страница 45: ...perating procedures for changing them Access the screen for initial setting 1 by taking procedures 8 2 Enter the mode for initial setting 1 Press F5 SELECT to open the screen for selecting the atmosph...

Страница 46: ...m the keyboard 4 Selection for Refraction Curvature Corrections CRV REF CORR Select whether the correction factor to be input for both differences Refraction Curvature is set to 0 14 0 2 or none NIL S...

Страница 47: ...5 Selection of Tilt display unit MIN UNIT ANG Select whether to set the minimum angle display mode to COARSE 5 seconds or FINE 1 second 6 Selection of Long range message LONG RANGE MES If you need th...

Страница 48: ...ment or for key entry has been performed with the angle remaining unchanged 11 Selection of Distance measurement automatic power off function EDM OFF Select the time interval 3 5 or 10 minutes for act...

Страница 49: ...lithium battery The lithium battery needs to be replaced in five years When the message Li batt voltage is low is shown on the display screen have the lithium battery replaced by the dealer from whom...

Страница 50: ...nit for Distance 4 Selection of Angle unit setting ANG UNIT Select DEG or DEC or GRD or MIL as the unit for Angle 8 12 Initial setting 5 1 Selection of Communication type COM TYPE 1 Selection of Trans...

Страница 51: ...t whether the control signal is effective or not 6 Selection of XON XOFF XON XOFF Select whether to enable or disable XON XOFF 7 Selection of Through command THROUGH COMMAND Select whether to disable...

Страница 52: ...1 F2 or F3 F4 to position the cursor to the desired item 9 2 Accessing by 007 The LTS 200 allows you to enter a special code of 007 with the alphanumeric keys to display specific initial setting Press...

Страница 53: ...MIN 20 MIN 30 MIN NIL 511 EDM OFF 3 MIN 5 MIN 10 MIN NIL 512 ILL OFF 3 MIN 5 MIN 10 MIN NIL 515 PRIORITY SELECT PRIM MEAS KEY MEAS SHOT 515 517 PRIORITY SELECT COMP AXIS SEC MEAS KEY MEAS SHOT MEAS CO...

Страница 54: ...t is completed be sure that adjusting screws are completely tightened When finishing turning adjusting screws be sure that screws are turned in a direction for tightening Repeat check after adjustment...

Страница 55: ...he instrument is rotated by 180 When the bubble moves repeat from 1 once again 11 2 Circular vial Checks Adjust by the plate level vial beforehand Confirm the position of the bubble of the circular vi...

Страница 56: ...h telescope Using the telescope fine adjustment screws move Point A to the edge of the field of view by screw Point A No adjustment is necessary if Point A moves along the vertical line of the reticle...

Страница 57: ...t B With the telescope still reversed loosen the horizontal lock screw and rotate the instrument around the vertical axis and sight Point A again Loosen the telescope lock screw and turn the telescope...

Страница 58: ...ngle R If y R 360 no further adjustment is necessary Adjustments If the deviation d y R 360 is wide contact your local dealer 11 6 Laser plummet Checks Set the instrument on the tripod and place a pie...

Страница 59: ...e line It can also be obtained in a simple way as described below Checks Locate points A B and C at about 50m intervals on even ground Set up the instrument at point A and measure the distances betwee...

Страница 60: ...le in case of rapid temperature change shock or aging Check your instrument by following procedures Checks Install the instrument on the tripod and level it at the distance of approx 50m from the wall...

Страница 61: ...tre of laser spot is not within the internal circle 10mm of the target plate the adjustment is necessary Please contact your LINERTEC dealer 10mm 20mm Internal circle Example Adjustment is necessary E...

Страница 62: ...easurable distance of LTS 200 series is measured with a wrong target mode Please select a correct target then measure If a wrong target is selected a correct distance cannot be measured Select the cor...

Страница 63: ...oblem of the internal EDM parameters ERROR ETH DATA Problem of the internal ETH parameters 12 2 Atmospheric correction The speed at which light travels through the air varies depending on the temperat...

Страница 64: ...0 613 627 640 653 500 667 680 693 707 720 733 747 760 773 787 600 800 813 827 840 853 867 880 893 907 920 700 933 947 960 973 987 1000 1013 1027 1040 1053 800 1067 1080 1093 1107 1120 1133 1147 1160 1...

Страница 65: ...6 11 4 14 2 5 6 3 3 5 1 0 2 2 5 1 8 0 10 8 13 7 5 7 6 4 7 2 1 1 3 4 2 7 2 10 2 13 1 15 9 0 5 9 3 2 0 2 3 3 6 4 9 5 12 6 Error table With mmHg 15 C 760mmHg as standard Unit mm C mmHg 900 800 760 700 60...

Страница 66: ...ngle are caused to determine the horizontal distance and the height differenTIAl With this instrument the following formula is used to correct these factors Calculation formula when atmospheric refrac...

Страница 67: ...e Normal With this instrument the conditions noted below are used to differenTIAte between the two situations good weather conditions for surveying are different from normal weather conditions and in...

Страница 68: ...rotary encoder Vertical Horizontal angle 2 sides 30 2mm Visible Laser 0 5mm instrument height 1 5m Erect 30 x 183 W x 342 H x 167 L mm 5 4kgs 440 W x370 H x275 L mm 3 9 kgs Li ion 4400mAh 3000m 2 2pp...

Страница 69: ...r Good conditions 40km visibility with overcast no heat no shimmer and moderate wind 4 EDM measuring time is determined in good conditions It may takes longer than usual to measure the distance exceed...

Страница 70: ...ecifications of Laser Radiation A The EDM module of the LTS 200 produces a visible light beam which is emitted from the telescope objective lens and the centre hole of the instrument base plate The LT...

Страница 71: ...lass IIIa laser product B Caution label is located near the exit aperture AVOID EXPOSURE Laser radiation is emitted from this aperture C Warning logotype is located on the surface of the telescope CAU...

Страница 72: ...Pressing Laser key and F2 RED MARK key can terminate the laser beam emission by the laser pointer F The laser beam emission by the laser plummet can be terminated by pressing laser key and F4 PLUM ADJ...

Страница 73: ...ification Laser beam is transmitted from this aperture Warning logotype Warning logotype LED is turned on at the time of emission For North America Certification Warning logotype Aperture label Laser...

Страница 74: ......

Страница 75: ......

Страница 76: ...1 TI Asahi Co Ltd International Sales Department 4 3 4 Ueno Iwatsuki Ku Saitama Shi Saitama 339 0073 Japan Tel 81 48 793 0118 Fax 81 48 793 0128 E mail trade tilinertec com LTS200_Basic01A...