59
12. APPENDIX
12.1 Warning and Error Messages
Warning
Message
Meaning
What to do
Out of tilt range Displayed when the instrument is tilted
beyond the vertical compensation range
(±3’) in case automatic compensation is
selected.
When it is properly leveled, this message
may be temporarily displayed if the
instrument is turned too fast.
Re-level the instrument.
Repair is needed if the
message is displayed
when it is properly
levelled.
Excess data
The input data exceeds the allowable
range.
Press the [ESC] key and
enter the correct data.
Out of range
(
when being lit
)
This message is displayed if a long
distance which is far beyond measurable
distance of LTS-200 series is measured
with a wrong target mode.
Please select a correct target then
measure.
If a wrong target is selected, a correct
distance cannot be measured.
Select the correct target
mode.
Out of range
(when flashing)
The measurement distance is less than
1.5m in Reflector sheet mode.
The measurement distance is less than
5m in Prism mode.
Select a longer point, or
use a tape measurer.
Unsuitable
Condition
Under too strong sunlight.
Unstable light value owing to shimmer or
obstacles.
Reflector sheet, Target and Prism do not
face the instrument.
Reflector sheet, Target and Prism are not
correctly sighted.
Measurement range is over in
Reflectorless mode.
Sufficient signal does not return by
Change the object that
has much better
reflectivity or use a prism,
or wait until the sun
activity has weakened.