34
the [F1] [MEAS] again terminates both distance measurement and blinking of the “MEAS”
text.
• Pressing[F5][MODE]and [F1] [DISP] cycles through the sets of display
items:“H.angle/H.dst./V.dst.”, “H.angle/V.angle/S.dst.”, and
“H.angle/V.angle/H.dst./S.dst./V.dst.”
• Pressing the [ESC] or [F2] [TARGET] or [F5] [MODE] during distance measurement
stops it.
• If the shot count for distance measurement has been set to 2 or more in “initial setting 2”,
the distance is measured for the specified number of times to display the averaged value.
Example: “TRACK CONT” at second MEAS (Factory default setting)
Collimate the telescope at a Target and press [F1]
[MEAS] twice to start measuring the distance. Upon
reception of a reflected light from the target, the
instrument beeps and displays the mark to start the
TRACK distance measurement.
• Press [F1] [MEAS ] twice.
• Pressing [F1] [MEAS] twice after collimating the telescope at the Target starts Continuous
distance measurement at fast speed with the “MEAS” text blinking.
It remains blinking during the measurement. If you press the [F1] [MEAS] again, Distance
measurement is completed and the “MEAS” text stops blinking.
• Pressing [F5][MODE]and[F1] [DISP] cycles through the sets of display tems:
“H.angle/H.dst./V.dst.”, “H.angle/V.angle/S.dst.”, and
“H.angle/V.angle/H.dst./S.dst./V.dst.”
• Pressing the [ESC] or [F2] [TARGET] or [F5] [MODE] during fast distance measurement
stops it.