-57-
Operation
Press [RUN] and data in the selected buffer on the TXD or RXD will be transmitted from the oldest data. Data is
transmitted by one frame unit continuously spacing "Idle time".
◆
Limitation of operation
・
If one frame contains more than 4K characters, analyzer divides its data and sends the first 4K characters.
・
Framing error of ASYNC is transmitted as normal data. (not as error)
・
Aborted frame of HDLC/SDLC is not transmitted but a flag is transmitted in the place where aborted frame
is generated.
・
Information of Idle time in the buffer is not going to be used.
・
Information of control line in the buffer is not going to be used. When the analyzer is DTE mode, RTS and
DTR will be in an active state at the beginning of test. And, when the analyzer is DCE mode, CTS, DSR
and DCD will be in an active state.
Press [STOP] to stop transmission and simulation.
4.6 Flow Mode
In the flow control test, the analyzer works as a transmitter or a receiver. It can simulate flow control signals such as
X-ON/X-OFF characters and handshake of control line.
Setting
Before starting the Flow simulation, set protocol and communication conditions in the "
Configuration
", and reg-
ister transmission data in the data table.
2.5 Communication Condition
4.1 Register Transmission Data
Press [MENU] and touch “Operation mode: Simulation” ->
“ Function
": FLOW”.
Touch “Advanced settings ” in the bottom of screen.
ڦ
Test Mode
Select “Send test” if analyzer becomes the transmitter. Select “Receive test” if analyzer becomes the receiver.