113
Rev. B
PMBus COMMAND DETAILS
TELEMETRY
COMMAND NAME
CMD
CODE DESCRIPTION
TYPE
PAGED FORMAT UNITS
NVM
DEFAULT
VALUE
READ_VIN
0x88 Measured input supply voltage.
R Word
N
L11
V
NA
READ_IIN
0x89 Measured input supply current.
R Word
N
L11
A
NA
READ_VOUT
0x8B Measured output voltage.
R Word
Y
L16
V
NA
READ_IOUT
0x8C Measured output current.
R Word
Y
L11
A
NA
READ_TEMPERATURE_1
0x8D Power stage temperature sensor. This is
the value used for all temperature related
processing, including IOUT_CAL_GAIN.
R Word
Y
L11
C
NA
READ_TEMPERATURE_2
0x8E Internal junction temperature. Does not affect
any other controller commands.
R Word
N
L11
C
NA
READ_FREQUENCY
0x95 Measured PWM switching frequency.
R Word
Y
L11
Hz
NA
READ_POUT
0x96 Calculated output power.
R Word
Y
L11
W
NA
READ_PIN
0x97 Calculated input power.
R Word
N
L11
W
NA
MFR_PIN_ACCURACY
0xAC Returns the accuracy of the READ_PIN command
R Byte
N
%
5.0%
MFR_IOUT_PEAK
0xD7 Report the maximum measured value of
READ_IOUT since last MFR_CLEAR_PEAKS.
R Word
Y
L11
A
NA
MFR_VOUT_PEAK
0xDD Maximum measured value of READ_VOUT
since last MFR_CLEAR_PEAKS.
R Word
Y
L16
V
NA
MFR_VIN_PEAK
0xDE Maximum measured value of READ_VIN since
last MFR_CLEAR_PEAKS.
R Word
N
L11
V
NA
MFR_TEMPERATURE_1_PEAK 0xDF Maximum measured value of external
Temperature (READ_TEMPERATURE_1) since
last MFR_CLEAR_PEAKS.
R Word
Y
L11
C
NA
MFR_READ_IIN_PEAK
0xE1 Maximum measured value of READ_IIN
command since last MFR_CLEAR_PEAKS.
R Word
N
L11
A
NA
MFR_READ_ICHIP
0xE4 Measured current used by the LTM4680.
R Word
N
L11
A
NA
MFR_TEMPERATURE_2_PEAK
0xF4 Peak internal die temperature since last
MFR_CLEAR_PEAKS.
R Word
N
L11
C
NA
MFR_ADC_CONTROL
0xD8 ADC telemetry parameter selected for repeated
fast ADC read back.
R/W Byte
N
N
Reg
NA
READ_VIN
The READ_VIN command returns the measured V
IN
pin voltage, in volts added to READ_ICHIP • MFR_RVIN. This
compensates for the IR voltage drop across the V
IN
filter element due to the supply current of the LTM4680.
This read-only command has two data bytes and is formatted in Linear_5s_11s format.
READ_VOUT
The READ_VOUT command returns the measured output voltage by the VOUT_MODE command.
This read-only command has two data bytes and is formatted in Linear_16u format.