109
Rev. B
STATUS_VOUT
The STATUS_VOUT command returns one byte of V
OUT
status information.
STATUS_VOUT Message Contents:
BIT
MEANING
7
V
OUT
overvoltage fault.
6
V
OUT
overvoltage warning.
5
V
OUT
undervoltage warning.
4
V
OUT
undervoltage fault.
3
V
OUT
max warning.
2
TON max fault.
1
TOFF max fault.
0
Not supported (LTM4680 returns 0).
The user is permitted to write a 1 to any bit in this command to clear a specific fault. This permits the user to clear
status by means other than using the CLEAR_FAULTS command.
Any supported fault bit in this command will initiate an
ALERT
event.
This command has one data byte.
STATUS_IOUT
The STATUS_IOUT command returns one byte of I
OUT
status information.
STATUS_IOUT Message Contents:
BIT
MEANING
7
I
OUT
overcurrent fault.
6
Not supported (LTM4680 returns 0).
5
I
OUT
overcurrent warning.
4:0
Not supported (LTM4680 returns 0).
The user is permitted to write a 1 to any bit in this command to clear a specific fault. This permits the user to clear
status by means other than using the CLEAR_FAULTS command.
Any supported fault bit in this command will initiate an
ALERT
event. This command has one data byte.