background image

3

Hardware Features

  BUILT-IN RADIO RECEIVER

Variable gain, high-sensitivity receiver for wireless transmitters

  FOUR FORM “C” (N.O. & N.C) RELAYS

Each relay has 3-amp @ 24-volt rating

  FOUR REQUEST-TO-EXIT INPUTS

Activates access device for exiting using a hardwired switch

  FOUR SENSING INPUTS

For sensing door position to control door-ajar and alarm features, or for access inhibit timer

 BUILT-IN ANNUNCIATOR

Chirps during keystrokes

 BUILT-IN MODEM

No add-on modem required for telephone communications with system

 RS-232 PORT

COM port for direct connection to a computer

 NETWORK SUPPORT

Multiple units can be connected together to share data

  EXPANSION INTERFACE SUPPORT

Model AM-MIO accessory adds additional input and outputs to the AE2000Plus

  ON-BOARD CLOCK/CALENDAR CIRCUIT

Stamps the event log data as it is stored in the system’s memory

 WIEGAND INPUTS

Two Wiegand format card reader inputs for connection to external devices.

  LINEAR PBUS SUPPORT

Three PBUS input/output ports for connection of up to 6 Linear accessories.

  CCTV COLOR CAMERA SUPPORT

Model CCM-1 accessory camera allows color video monitoring of the keypad area

  POWER FAILURE MONITOR

AC power input is monitored, power outages are recorded in the event log

Software Highlights

 COMPUTER PROGRAMMABLE

No dedicated programmer required, program with a computer and a modem

  LARGE ENTRY CODE CAPACITY

Up to 20,000 entry codes can be used for gaining access

  2-8 DIGIT ENTRY CODE LENGTH

Flexible code length for different applications

  LARGE RESIDENT DIRECTORY CAPACITY

Up to 10,000 residents

  2-4 DIGIT DIRECTORY NUMBER LENGTH

Directory number lengths can be customized for small or large installations

  LARGE TRANSMITTER CAPACITY

Up to 45,600 block coded and 20,000 individually enrolled Linear transmitters can be used 
for gaining access

  TRANSMITTER FACILITY CODE SUPPORT

Identifi es wireless transmitters by installation

  LARGE CARD CAPACITY

Up to 45,600 block coded and 20,000 individually enrolled cards can be used for gaining access

  FOUR INDEPENDENT RELAY CHANNELS

Each output’s action is programmable

  PROGRAMMABLE TIME SCHEDULED RELAY ACTIVATION

Activation for up to four time periods for each of the 31 system time zones

  PROGRAMMABLE TIME ZONE ACCESS VALIDATION

Validation during four time periods for each of the 31 system time zones

  PROGRAMMABLE VALIDATION DAYS

Select days of the week access is allowed

  PROGRAMMABLE HOLIDAY DAYS

Select up to 24 expiring & 24 non-expiring holidays for access restriction

  OBSTACLE TRANSMITTER SUPPORT

Compatible with Linear’s Model MGT transmitter

 EVENT LOG

Stores up to 20,000 system events in memory for record keeping

  DELETED CARDHOLDER DATABASE

System logs deleted cardholders for future identifi cation

  TIMED OR TRUE ANTI-PASSBACK

Options to temporarily disable a cardholder’s credentials after access for a preset time or 
depending on the cardholder’s access direction

Feature Overview

Relay Outputs

Four 3-amp dry contact relay outputs are provided to activate access devices, 
such as door strikes, magnetic locks, automatic doors, barrier gates, and 
automatic sliding gates. The relay outputs can also be used as specialty 
outputs for alarm contact shunting, operator obstacle triggering, and alarm 
activation. Each of the relays can also be manually activated from buttons on 
the AE2000Plus circuit board. LED indicators display the status of each relay.

Request-to-Exit Inputs

Each relay channel has a request-to-exit input. These inputs are supplied for 
hardwire activation of the access devices. Typically a request-to-exit input is 
wired to a pushbutton inside of the access controlled area. When a person 
desires to exit, pressing the pushbutton will activate the output relay channel 
and trigger the access device. A loop detector for automatic gate operation 
can be connected to a request-to-exit input.

Sensing Inputs

The sensing inputs connect to door switches that monitor whether the controlled 
door is open or closed. The sensing inputs may alternately be programmed as 
“access inhibit” inputs for use with an external timer or service switch.

Built-in Modem

A modular connector is provided for telephone line connection to the unit’s 
built-in 33.6K baud modem. The system can be accessed remotely for 
programming and control over the standard telephone system using a 
personal computer with a modem. For system backup, a computer connected 
through the modem can store and retrieve the AE2000Plus’s memory data.

RS-232 Communications Port

A modular connector is provided for the bi-directional 38.4K baud RS-232 
port. The AE2000Plus’s RS-232 port connects to a personal computer’s 
COM port. System programming can be performed locally with a computer 
connected to the RS-232 port.

Local Keypad

The local keypad is the system’s primary keypad. The local keypad activates 
Relay Channel “A”, but can be programmed for any of the relays.

Postal Lock

The AE2000Plus cabinet has provisions for installing a U.S.P.S. postal lock for 
keyed mail carrier access. The postal lock will activate Relay Channel “A”, but 
can be programmed for any of the relays.

Obstacle Detection

Linear’s Model MGT safety edge transmitter is compatible with the AE2000Plus. 
The MGT detects and transmits obstacle events to the AE2000Plus.

Programming Memory

The AE2000Plus fl ash memory retains all entry codes, transmitter information, 
card access, and programming, even without power.

Battery Backup

The system supports a 12-volt battery backup or uninterruptable power supply 
for operation during power outage. The system does not charge the backup 
battery, an external battery charger is required to maintain the battery.

Network Support

Multiple AE1000Plus, AE2000Plus, & AM3Plus units can be networked 
together via three-wire RS-485 cables or through modems allowing 
information sharing between the units. A common event log is retained for all 
of the networked units.

Linear PBUS Ports

Three 6-wire Linear PBUS input/output ports are available to connect to 
several accessories (keypads, proximity readers, remote receivers). A typical 
application for a remote keypad or reader would be to control additional doors 
or gates.

Содержание AE2000PLUS

Страница 1: ...USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com AE2000Plus Telephone Entry Access Control System Installation Instructions...

Страница 2: ...mote receivers card readers and interior and exterior keypads can be used with the system BlockcodedMegaCode transmitterscanbeusedtogainaccessthrough the AE2000Plus s built in or remote radio receiver...

Страница 3: ...outputs are provided to activate access devices such as door strikes magnetic locks automatic doors barrier gates and automatic sliding gates The relay outputs can also be used as specialty outputs f...

Страница 4: ...dard single gang electrical box Tamper resistant screws secure the keypad to its mounting plate The die cast keys have bright easy to read yellow graphics and is illuminated with white LEDs The keypad...

Страница 5: ...NECTOR CAMERA CONNECTOR HIDDEN OPTIONAL CAMERA PBUS TERMINALS NETWORK TERMINALS AM MIO INTERFACE TELEPHONE INTERFACE CONNECTOR TAMPER MAGNET SYSTEM RESTART BUTTON RESIDENT S VOICE VOLUME ADJUSTMENT FO...

Страница 6: ...COM N C RTE C RELAY CHANNEL C TERMINALS RELAY CHANNEL D TERMINALS RELAY RATING 3 AMPS 30 VOLTS AC DC MAXIMUM EARTH GROUND STAKE GROUND STUD WIEGAND DEVICE LED2 HOLD LED1 DAT 1 DAT 0 GND PWR WIEGAND DE...

Страница 7: ...isolated from the AE2000Plus NEVER MOUNTTHE UNIT DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AE2000Plus is used to control a gate operator connected to a vehicular gate the unit MUST b...

Страница 8: ...remove the green ground wire lug from the stud 3 Remove the two bottom circuit board mounting plate nuts 4 Loosen the two top circuit board mounting plate nuts 5 Carefully lift up on the mounting pla...

Страница 9: ...edestal Mounting The cabinet can be mounted on a gooseneck pedestal Linear manufacturers two pedestals Model GNC 1 is for surface mounting with concrete fasteners Model GNB 1 is for burial mounting Wh...

Страница 10: ...inputs are typically used with push bars loop sensors or pushbuttons 1 Install the pushbutton or device to signal an exit request 2 Route two wires from the device to the AE2000Plus 3 Connect the dev...

Страница 11: ...ct the Battery positive to the AE2000Plus DC terminal and the negative to the DC terminal NOTE The AE2000Plus does not supply battery charging current An external battery charger will be required to m...

Страница 12: ...cable The antenna connector should be mounted on a metal surface using a 3 8 hole Two other models of antennas are compatible with the AE2000Plus The Model EXA 1000 is a non directional antenna The M...

Страница 13: ...rammed output relay will activate Postal Lock Installation 1 After opening the cabinet re lock the left cabinet lock to provide clearance to remove the postal lock switch plate 2 Remove the four lockn...

Страница 14: ...puts WIEGAND A B can connect to a large variety of 26 30 and 31 bit Wiegand output accessories The Wiegand format is a common standard for access control equipment A typical application would be to ad...

Страница 15: ...supported AXNET network hardware configurations and associated Network Configuration Numbers After choosing a network layout that best suits the installation note the Network Configuration Number Thi...

Страница 16: ...ight networks each with eight nodes for a total of 64 units RS 485 CABLE CONNECTION NETWORK NODE 1 ALWAYS REQUIRES A MODEM FOR REMOTE PROGRAMMING MODEM UNIT NETWORK NODE FULL ACCESSBASE2000 NETWORK NO...

Страница 17: ...b or by wiring from one unit to the next in daisy chain fashion See the figures for wiring options Use Belden 9925 or Carol C0600 shielded cable or equivalent Maximum wire run distance is 4000 feet NO...

Страница 18: ...g operation When calling for technical assistance Linear s Technical Services Department may ask the installer to use these components to diagnose the system On board Indicators 17 LED indicators are...

Страница 19: ...ion is displayed press the ENTER button to select the option NOTE In network installations a unique network address 1 8 for AccessBase2000 1 4 for AXNET must be set before communicating with network N...

Страница 20: ...m will dial the resident s telephone number to establish 2 way communications NOTE The resident s telephone number will never be displayed to the visitor If the resident is using the telephone at the...

Страница 21: ...t DC source 6 amp hr minimum Outputs Relay Channels A D Form C 3 Amps 30 Volts maximum Inputs Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Th...

Страница 22: ...o many incorrect attempts Wait one minute for lockout to clear and try again 3 Remote keypad wiring incorrect Resident s Telephone does not ring when a visitor calls 1 Resident s telephone number prog...

Страница 23: ...421 1587 for an RPA and other important details FCC Notice Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user s authority to operate t...

Страница 24: ...Copyright 2008 Linear LLC 227541 B...