Troubleshooting

System completely dead

1.  No power from transformer. Check voltage at transformer terminals.
2.  Check voltage at AE2000Plus power terminal strip.

Buzz on speaker

1.  Check for 24 volt AC power shorted to wiring conduit.
2.  Check for telephone line shorted to ground.
3.  Verify that telephone wires are twisted pair.
4.  Verify that the AE2000Plus is connected to earth ground.
5.  Check 16 VAC voltage at AE2000Plus transformer terminals.

Buzz on telephone line

1.  Disconnect 16 VAC wires from terminal strip, if buzz goes away, 

one side of the transformer wires is grounded.

2.  Check all connections for any shorts to ground.

System will not answer an incoming call

1.  Automatic telephone answer disabled.
2.  AE2000Plus telephone line trouble.

Entry code will not activate relay

1.  Entry code not assigned.
2.  Entry code not set up for proper relay.
3.  Keypad is in lockout.

Remote PBUS device does not work

1.  Check remote device address switch setting.
2.  Check remote device for power.
3.  Be sure the device is wired correctly.

Main or remote keypad will not activate a relay

1.  Entry code is not assigned.
2.  Keypad may be in lockout from too many incorrect attempts. Wait 

one minute for lockout to clear and try again.

3.  Remote keypad wiring incorrect.

Resident’s Telephone does not ring when a visitor calls

1.  Resident’s telephone number programmed incorrectly.
2.  Check AE2000Plus telephone line.
3.  Call resident from another line or cell phone to determine if the 

resident’s telephone is working.

Transmitter does not activate relay

1.  Transmitter button setting programmed to “none” (would effect all 

transmitters).

2.  Transmitter not enrolled.
3.  Specifi c transmitter is deactivated in the system.

Poor transmitter radio range

1.  Check antenna installation and condition if transmitters were 

previously working well.

2. Check 

the 

RADIO

 indicator on the AE2000Plus circuit board. If it 

is fl ickering without activating any transmitters there is interference 
blocking the receiver. Try adjusting the 

RECEIVER RAN

G

E

 knob 

to reduce the receiver’s sensitivity to the interference.

3.  Connect an audio amplifi er or telephone buttset to the 

RECEIVER 

TEST POINTS

 (the wire jumpers next to the 

RECEIVER RAN

G

E

 

knob). Listen to the sounds of the signals being received. If you 
hear the interference, remove power from possible interfering 
devices to determine the source of the interference. The antenna 
or the interfering device may need to be relocated.

4.  Use Model FT-1 to check for interference.

Содержание AE2000PLUS

Страница 1: ...USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com AE2000Plus Telephone Entry Access Control System Installation Instructions...

Страница 2: ...mote receivers card readers and interior and exterior keypads can be used with the system BlockcodedMegaCode transmitterscanbeusedtogainaccessthrough the AE2000Plus s built in or remote radio receiver...

Страница 3: ...outputs are provided to activate access devices such as door strikes magnetic locks automatic doors barrier gates and automatic sliding gates The relay outputs can also be used as specialty outputs f...

Страница 4: ...dard single gang electrical box Tamper resistant screws secure the keypad to its mounting plate The die cast keys have bright easy to read yellow graphics and is illuminated with white LEDs The keypad...

Страница 5: ...NECTOR CAMERA CONNECTOR HIDDEN OPTIONAL CAMERA PBUS TERMINALS NETWORK TERMINALS AM MIO INTERFACE TELEPHONE INTERFACE CONNECTOR TAMPER MAGNET SYSTEM RESTART BUTTON RESIDENT S VOICE VOLUME ADJUSTMENT FO...

Страница 6: ...COM N C RTE C RELAY CHANNEL C TERMINALS RELAY CHANNEL D TERMINALS RELAY RATING 3 AMPS 30 VOLTS AC DC MAXIMUM EARTH GROUND STAKE GROUND STUD WIEGAND DEVICE LED2 HOLD LED1 DAT 1 DAT 0 GND PWR WIEGAND DE...

Страница 7: ...isolated from the AE2000Plus NEVER MOUNTTHE UNIT DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AE2000Plus is used to control a gate operator connected to a vehicular gate the unit MUST b...

Страница 8: ...remove the green ground wire lug from the stud 3 Remove the two bottom circuit board mounting plate nuts 4 Loosen the two top circuit board mounting plate nuts 5 Carefully lift up on the mounting pla...

Страница 9: ...edestal Mounting The cabinet can be mounted on a gooseneck pedestal Linear manufacturers two pedestals Model GNC 1 is for surface mounting with concrete fasteners Model GNB 1 is for burial mounting Wh...

Страница 10: ...inputs are typically used with push bars loop sensors or pushbuttons 1 Install the pushbutton or device to signal an exit request 2 Route two wires from the device to the AE2000Plus 3 Connect the dev...

Страница 11: ...ct the Battery positive to the AE2000Plus DC terminal and the negative to the DC terminal NOTE The AE2000Plus does not supply battery charging current An external battery charger will be required to m...

Страница 12: ...cable The antenna connector should be mounted on a metal surface using a 3 8 hole Two other models of antennas are compatible with the AE2000Plus The Model EXA 1000 is a non directional antenna The M...

Страница 13: ...rammed output relay will activate Postal Lock Installation 1 After opening the cabinet re lock the left cabinet lock to provide clearance to remove the postal lock switch plate 2 Remove the four lockn...

Страница 14: ...puts WIEGAND A B can connect to a large variety of 26 30 and 31 bit Wiegand output accessories The Wiegand format is a common standard for access control equipment A typical application would be to ad...

Страница 15: ...supported AXNET network hardware configurations and associated Network Configuration Numbers After choosing a network layout that best suits the installation note the Network Configuration Number Thi...

Страница 16: ...ight networks each with eight nodes for a total of 64 units RS 485 CABLE CONNECTION NETWORK NODE 1 ALWAYS REQUIRES A MODEM FOR REMOTE PROGRAMMING MODEM UNIT NETWORK NODE FULL ACCESSBASE2000 NETWORK NO...

Страница 17: ...b or by wiring from one unit to the next in daisy chain fashion See the figures for wiring options Use Belden 9925 or Carol C0600 shielded cable or equivalent Maximum wire run distance is 4000 feet NO...

Страница 18: ...g operation When calling for technical assistance Linear s Technical Services Department may ask the installer to use these components to diagnose the system On board Indicators 17 LED indicators are...

Страница 19: ...ion is displayed press the ENTER button to select the option NOTE In network installations a unique network address 1 8 for AccessBase2000 1 4 for AXNET must be set before communicating with network N...

Страница 20: ...m will dial the resident s telephone number to establish 2 way communications NOTE The resident s telephone number will never be displayed to the visitor If the resident is using the telephone at the...

Страница 21: ...t DC source 6 amp hr minimum Outputs Relay Channels A D Form C 3 Amps 30 Volts maximum Inputs Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Th...

Страница 22: ...o many incorrect attempts Wait one minute for lockout to clear and try again 3 Remote keypad wiring incorrect Resident s Telephone does not ring when a visitor calls 1 Resident s telephone number prog...

Страница 23: ...421 1587 for an RPA and other important details FCC Notice Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user s authority to operate t...

Страница 24: ...Copyright 2008 Linear LLC 227541 B...

Отзывы: