background image

19

PPN 51

51#COUNT#

COUNT = NUMBER (1-9) OF INCORRECT ENTRIES

THAT WILL CAUSE A 90 SECOND LOCKOUT

KEYPAD LOCKOUT COUNT

FACTORY SETTING: 3 TRIES

PPN 57

57#LINE 1#LINE 2#

LINE 1 = UP TO 16 CHARACTERS TEXT
LINE 2 = UP TO 16 CHARACTERS TEXT

WELCOME DISPLAY TEXT

FACTORY SETTING: LINEAR ACCESS TELEPHONE ENTRY

PPN 61

61#ANSWER#

ANSWER = 0 FOR AUTO ANSWER OFF
ANSWER = 1 FOR AUTO ANSWER ON

AUTOMATIC TELEPHONE ANSWER

FACTORY SETTING: AUTO ANSWER ON

PPN 52

52#SECONDS#

SECONDS = ACTIVATION TIME (04-99 SECONDS)

ACCESS RELAY ACTIVATION TIME

FACTORY SETTING: 4 SECONDS

PPN 62

62#CHIRP#

CHIRP = 0 FOR KEYSTROKE CHIRP OFF
CHIRP = 1 FOR KEYSTROKE CHIRP ON

SPEAKER CHIRP ON KEYSTROKE

FACTORY SETTING: KEYSTROKE CHIRP ON

STANDARD PROGRAMMING METHOD

System Options (Continued)

Keypad Lockout Count

The system counts the number of invalid Entry Codes entered at the 
keypad. If the invalid entries exceeds the lockout count number, the 
keypad is locked out for 90 seconds. The factory setting for the lockout 
count is three. The lockout value can be from one to nine.

1. Press

 

 

 

2.  Enter the number for the lockout count (1-9).

3

. Press 

Access Relay Activation Time

The factory setting will cause the access relay to activate for 4 seconds. 
The activation time can be set from 4-99 seconds to accommodate 
different types of access control devices.

1. Press     

2.  Enter the time (in seconds) for access relay to stay activated (04-99)

3

. Press 

Welcome Display Text

The AE-100 display will show a visitor a welcome message alternating 
with instructions on how to fi nd and call a resident. The welcome message 
can be customized to suit the installation.

 

NOTE

:

 This step cannot be performed remotely through the telephone.

1. Press

 

 

 

 

NOTE

:

 To enter capital letters only, press

 

 fi rst before entering the text.

2.  Enter the new text for the top line of the display (up to 16 characters).

3

. Press 

 

NOTE

:

 To enter capital letters only, press

 

 fi rst before entering the text.

4.  Enter the new text for the bottom line of the display (up to 16 characters).

5. Press 

Automatic Telephone Answer

The factory setting will allow the system to detect a ring signal on the 
telephone line and answer the call.

 

NOTE

:

 The automatic answer feature can be turned off, although remote 

programming, remote access control by residents, and resident call-back 
features will no longer function.

1. Press

 

 

 

2.  Select the option for automatic telephone answering:

Enter 0 to turn OFF automatic telephone answering.

• 

Enter 1 to turn ON automatic telephone answering.

• 

3

. Press 

Speaker Chirp on Keystrokes

The factory setting will cause the speaker to chirp when each key on the 
keypad is pressed. Alternately, the speaker chirp can be turned off.

1. Press

 

 

 

2.  Select the option for keystroke speaker chirps:

Enter 0 to turn OFF the keystroke speaker chirps.

• 

Enter 1 to turn ON the keystroke speaker chirps.

• 

3

. Press 

Содержание ACCESS AE-100 Guide

Страница 1: ...340 www linearcorp com AE 100 Commercial Telephone Entry System PRINTER S INSTRUCTIONS INSTR INSTL AE 100 LINEAR P N 225787 C INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 SCALE 1 1 FOLDING A...

Страница 2: ...ice for the hearing impaired OPTIONAL COLOR CCTV CAMERA System supports a Model CCM 1 color CCD camera for viewing the visitor area FLEXIBLE TELEPHONE LINE CONNECTION Telephone line can connect to on...

Страница 3: ...call this feature gives residents the capability to talk to a visitor and grant access by using their entry code on the telephone s keys Operation In a typical installation the unit s memory is progra...

Страница 4: ...STAL LOCK OPTIONAL SPEAKER MICROPHONE CONNECTOR SPEAKER CONNECTOR DISPLAY CONTRAST ADJUSTMENT SPEAKERPHONE VOLUME ADJUSTMENT POSTAL LOCK MICROSWITCH RESET BUTTON FOR EASY WIRING THE UNIT S GREEN TERMI...

Страница 5: ...NECT TELEPHONE LINE TO TERMINALS OR TELEPHONE JACK 12 VOLT BATTERY WIRING NOTES 1 FOR POWER TRANSFORMER WIRE RUNS UP TO 100 FEET USE 18 AWG THHN 600 VOLT INSULATED WIRE 2 FOR POWER TRANSFORMER WIRE RU...

Страница 6: ...ted from the AE 100 NEVER MOUNT THE UNIT DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AE 100 is used to control a gate operator connected to a vehicular gate the unit MUST be mounted AT...

Страница 7: ...the inside of the cabinet Pedestal Mounting The cabinet can be mounted on a standard goose neck pedestal Linear offers two types of pedestals The Model GNC 1 is a 42 high curb mount pedestal P N ACP00...

Страница 8: ...piece 7 Drill 3 16 holes in the cabinet s six pre marked locations CAUTION After drilling remove any metal chips from the inside of the cabinet 8 The trim ring is supplied with four adhesive mylar sti...

Страница 9: ...CONDUIT Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring All telephone wiring must be made on the building side of the telephone company s...

Страница 10: ...At the master unit connect all the sub unit 2 conductor telephone cables to the master unit s TELEPHONE terminals polarity not important Multiple Units Daisy chain Wired 1 Mount and install the master...

Страница 11: ...with double stick tape or by using another secure method 1B For an external backup battery cut off the two spade lugs from the AE 100 s battery wires Route two red and black 18 AWG wires between the...

Страница 12: ...quire the use of a video amplifier NOTE The composite video signal can be viewed on a video monitor Alternately a Linear ChannelPlus brand video modulator can be used to convert the video signal to an...

Страница 13: ...ACCESS RELAY ACTIVATION ON 64 70 MAXIMUM VISITOR TALK TIME 60 SECONDS 71 08 ASSIGN UNIT NUMBER 1 77 77 RESIDENT CONTROL OF ACCESS RELAY ON 95 95 RESIDENT CALL BACK OFF ACCESS DATA CONTROL 21 01 ADD A...

Страница 14: ...correct the display will show ENTER FUNCTION 6 Programming commands can now be entered on the keypad Refer to the following sections of this manual for programming step details Also refer to the figu...

Страница 15: ...Prompts When programming over the telephone each programming step consists of entering programming data using the telephone s keypad The system will sound beeps over the telephone to indicate correct...

Страница 16: ...ure to set the unit number back to Unit 1 NOTE If one of the sub units goes down for service or is removed from the installation notify service personnel to reprogram this step on the master unit to r...

Страница 17: ...een set it can be modified to change a resident s Name Telephone Number or Entry Code NOTE This step cannot be performed remotely through the telephone 1 Press 2 Enter the resident s Directory Code 3...

Страница 18: ...ally 1 Press 2 Enter the new Stand alone Entry Code 3 Press 4 Enter the new Stand alone Entry Code again for verification 5 Press Deleting a Stand alone Entry Code Stand alone Entry Codes can be delet...

Страница 19: ...es 1 Press 2 Enter the time in seconds for access relay to stay activated 04 99 3 Press Welcome Display Text The AE 100 display will show a visitor a welcome message alternating with instructions on h...

Страница 20: ...nect the visitor after 60 seconds At ten and five seconds before the disconnect a tone will sound on the telephone to remind the resident of the pending disconnect The resident can extend the talk tim...

Страница 21: ...rformed from the master unit CAUTION This utility command will overwrite ALL the access data in the selected sub units 1 Press 2 Enter the unit number s of all of the sub units to receive the access d...

Страница 22: ...ually from the keypad for a period of hours 1 Press 2 Enter the amount of time in hours 01 98 for the access relay to latch 3 Press Latch Access Relay For servicing or testing while in Programming Mod...

Страница 23: ...s keypad select which programming method is used for the current programming session Entering programming by pressing keys together will select the Alternate Programming Method other manufacturer s st...

Страница 24: ...cannot be duplicated 3 Each Directory Code represents one tenant 4 Delete unused Directory Codes to avoid running out of memory 5 Tenant Names can be entered in any order The system will display the...

Страница 25: ...wo seconds to enter 1 4 two second pauses Note each pause entered counts as one of the 14 digits allowed in the telephone number Step 7 To keep the Access Code press Step 8 To change the Access Code e...

Страница 26: ...he Directory Code length factory default is 3 digits NOTE In multi unit installations if sub units are being updated with access data that has Directory Codes with more digits than the sub unit is set...

Страница 27: ...to then press one short beep sounds Step 3 Enter 5 for verification then press two short beeps sound Any entry other than 5 will cancel the command NOTE To allow for multi unit network communications...

Страница 28: ...y over the telephone the system will disconnect your call after Step 3 then copy the data from the master unit to the sub units 35 DISPLAY CLEAR SYSTEM ERRORS The system s power indicator will flash i...

Страница 29: ...unction Code 70 then press Step 2 The display will show the current talk time setting Enter the new talk time 010 180 seconds Step 3 Press Step 1 Enter Function Code 70 and press one short beep sounds...

Страница 30: ...ction Code 75 and press one short beep sounds Step 2 Enter 0 to turn the keystroke chirps OFF Enter 1 to turn the keystroke chirps ON Step 3 Press two short beeps sound 76 SPEAKER TONE ON ACCESS RELAY...

Страница 31: ...Function Code 93 again for verification then press NOT AVAILABLE 95 TENANT CALL BACK The tenant call back feature allows the AE 100 to answer the telephone and switch to speakerphone mode if the tele...

Страница 32: ...he viewing angle of the display in the installation causes the display to look too dark or too light the display s contrast can be adjusted 1 Locate the DISPLAY CONTRAST adjustment on the main circuit...

Страница 33: ...he resident answers the call and converses with the visitor to determine if access should be granted The resident can use their telephone s keypad to grant access activating the access relay by pressi...

Страница 34: ...Power 16 VAC from supplied plug in transformer Current Consumption 200 mA idle 500 mA operating Backup Battery 12 Volt sealed lead acid gel cell not included Built in charger with up to 7 A H battery...

Страница 35: ...uential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of removal installation or...

Страница 36: ...Copyright 2008 Linear LLC 225787 C...

Отзывы: