background image

2

dc2195afb

DEMO MANUAL DC2195A

Quick start proceDure

DC2195A is easy to set up to evaluate the performance 

of the LT8609. Refer to Figure 4 for proper measurement 

equipment setup and follow the procedure below:
NOTE: When measuring the input or output voltage ripple, 

care must be taken to avoid a long ground lead on the 

oscilloscope probe. See Figure 5 for the proper scope 

technique. 
1. Set an input power supply that is capable of 42V/2A. 

Then turn off the supply.

2. With power off, connect the supply to the input terminals 

V

EMI

 and GND.

3. Turn on the power at the input.
NOTE: Make sure that the input voltage never exceeds 42V.
4. Check for the proper output voltage of 5V. Turn off the 

power at the input.

5. Once the proper output voltage is established, connect 

a variable load capable of sinking 2A at 5V to the output 

terminals V

OUT

 and GND. Set the current for 0A.

a. If efficiency measurements are desired, an ammeter 

can be put in series with the output load in order to 

measure the DC2195A’s output current.

b. A voltmeter can be placed across the output terminals 

in order to get an accurate output voltage measurement.

6. Turn on the power at the input.
NOTE: If there is no output, temporarily disconnect the 

load to make sure that the load is not set too high.
7. Once the proper output voltage is again established, 

adjust the load and/or input within the operating range 

and observe the output voltage regulation, ripple volt-

age, efficiency and other desired parameters.

8. An external clock can be added to the SYNC ter-

minal  when  SYNC  function  is  used (JP1  on  the 

SYNC position). Please ensure that the chosen R

T

 

sets the LT8609 switching frequency to equal or 

below  the  lowest  SYNC  frequency.  See  the  data 

sheet section, “Synchronization.”

Figure 1. Efficiency vs Load Current at 2MHz Switching Frequency

I

OUT

 (A)

0

EFFICIENCY (%)

100

90

70

80

60

95

75

55

85

65

50

1.5

DC2195 F01

2

1

0.5

12V INPUT

24V INPUT

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Содержание DC2195A

Страница 1: ...LT LTC LTM Linear Technology and the Linear logo are registered trademarks of Linear Technology Corporation All other trademarks are the property of their respective owners Performance Summary move JP...

Страница 2: ...cy measurements are desired an ammeter can be put in series with the output load in order to measure the DC2195A s output current b A voltmeter can be placed across the output terminals inordertogetan...

Страница 3: ...rtical VIN 14V VOUT 5V IOUT 2A 2MHz Switching Frequency Spread Spectrum Mode operation Figure 3 LT8609 Demo Circuit EMI Performance in CISPR25 Radiated Emission Test Antenna Polarization Horizontal VI...

Страница 4: ...Start Procedure POWER SUPPLY IIN VIN IOUT LOAD Figure 4 Proper Measurement Equipment Setup Figure 5 Measuring Output Ripple VOUT GND Downloaded from Arrow com Downloaded from Arrow com Downloaded fro...

Страница 5: ...DEMO MANUAL DC2195A Quick Start Procedure Figure 6 DC2195A 1A to 2A Load Transient Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded fr...

Страница 6: ...A 12 1 U1 IC REGULATOR MSE10 LINEAR TECH LT8609EMSE PBF Additional Demo Board Circuit Components 1 1 C1 CAP ALUM 22 F 63V SUN ELECT 63CE22BS 2 2 C3 C10 CAP X7R 4 7 F 50V 10 1206 MURATA GRM31CR71H475K...

Страница 7: ...CTRUM PULSE SKIPPING BURST VOUT VCC VCC E6 EN UV R2 18 2k E5 SYNC R4 1 00M C1 22 F 63V L1 2 2 H XFL4020 222MEC E9 GND E7 TR SS C6 47 F 10V 1210 C11 1 F 50V 0805 C8 0 01 F C10 4 7 F 50V 1206 C4 0 22 F...

Страница 8: ...IS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES The user assumes all responsibility and liability for proper and safe handling of t...

Отзывы: