Troubleshooting

7

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Motor will not run

Disconnect switch is off

Be sure switch is on.

Fuse is blown or circuit breaker tripped

Replace fuse or reset circuit breaker.

Wires at motor are loose, 

DISCONNECT POWER; check and tighten all wiring.

disconnected, or wired incorrectly 

Pressure switch contacts are dirty

DISCONNECT POWER and clean the electrical contacts.

Motor runs hot and 

Voltage is too low

Check with power company. Install heavier wiring if wire size is too small.

overload kicks off

Pump cycles too frequently

See section below on too frequent cycling.

Motor runs but no 

Pump in new installation did 

In new installation:

water is delivered*

not pick up prime through: 

1. Improper priming 

1. Re-prime according to instructions.

2. Air leaks

2. Check all connections on suction line with

shaving cream.

3. Leaking foot valve or check valve

3. Replace foot valve or check valve.

Pump has lost prime through:

In installation already in use:

1. Air leaks

1. Check all connections on suction line and well seal.

2. Water level below suction pipe inlet

2. Lower suction line into water and re-prime. If receding water level 

in well exceeds 16’ (5M), a deep well pump is needed.

Foot valve or strainer is plugged

Clean foot valve or strainer.

Ejector or impeller is plugged

Clean ejector or impeller (See Repair Parts page).

Check valve or foot valve is stuck shut 

Replace check valve or foot valve.

Pipes are frozen

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

Foot valve and/or strainer are 

Raise foot valve and/or strainer above bottom of water source.

buried in sand or mud

Clean foot valve and strainer.

Water level is too low for shallow well  

A deep well pump may be needed (over 16’ (5M) to water) 

setup to deliver water

to deliver water.

Pump does not 

Water level in well is lower than 

A deep well jet will be needed if your well is more than 16’ (5M)

deliver water to full 

estimated

depth to water.

capacity

Steel piping (if used) is corroded or 

Replace with plastic pipe where possible, otherwise with new steel pipe.

limed, causing excess friction
Piping is too small in size

Use larger piping.

Packed well point

Backflush well point or sink new point.

Pump delivers water but

Pressure switch is out of adjustment or

DISCONNECT POWER; adjust or replace pressure switch.

does not shut off or

contacts are welded together

pump cycles too

Faucets have been left open

Close faucets.

frequently

Venturi, nozzle or impeller is clogged

Clean venturi, nozzle or impeller (See Repair Parts page).

Standard pressure tank is waterlogged

Drain tank to air volume control port. Check AVC for defects. Check 

and has no air cushion

all connections for air leaks.

Pipes leak

Check connections.

Foot valves leak

Replace foot valve.

Air charge too low in pre-charged tank

DISCONNECT POWER and open faucets until all pressure is relieved.
Using tire pressure gauge, check air pressure in tank at valve stem 
located on the tank. If necessary, adjust air pressure in tank to 1.5 Bars
(22 psi). Check air valve for leaks (use shaving cream) and replace core  
if necessary.

Air spurts from faucets

Pump is picking up prime

When pump has picked up prime, it should pump solid water with no air.

Leak in suction side of pump

Suction pipe is sucking air. Check joints for leaks with shaving cream.

Well is gaseous

Consult factory about installing a sleeve in the well.

Intermittent over-pumping of well

Lower foot valve if possible, otherwise restrict pump discharge.

(Water drawn down below foot valve)

* (Note: 

Stop pump;

then check prime
before looking for
other causes.
Unscrew priming
plug and see if water
is in priming hole).

Содержание Rotobomba 500T0800

Страница 1: ...er operating installation or maintenance assistance Call 1 262 728 5551 2006 RPX797 Rev 4 4 06 OWNER S MANUAL Household Water Pump System Models 500T0800 and 500T1000 293 Wright St Delavan WI 53115 Ph...

Страница 2: ...uttered and properly lighted store properly all unused tools and equipment Keep visitors at a safe distance from the work areas Pump body may explode if used as a boost er pump unless relief valve cap...

Страница 3: ...the tinaco to the inlet of the pump This line must be without leaks and the same size or larger than the pump inlet size 3 Install a shut off valve in the suction line from the tinaco This will allow...

Страница 4: ...own Either wire can connect to either terminal 4 Attach the pressure switch cover Checking Tank Pressure The pressure tank is pre charged with air pressure This must be adjusted when first installed a...

Страница 5: ...Apply power 3 If the pump does not start up open a faucet to drain water from the pressure tank 4 Watch the pressure gauge and note at what pressure the pump starts 5 Close the faucet 6 Watch the pres...

Страница 6: ...he system by running it through one complete pumping cycle to make sure it works To do this open a faucet and bleed off pressure until the pump starts Close the faucet and when the pressure in the sys...

Страница 7: ...be needed over 16 5M to water setup to deliver water to deliver water Pump does not Water level in well is lower than A deep well jet will be needed if your well is more than 16 5M deliver water to fu...

Страница 8: ...tionary 1 111P0510 111P0510 6 Impeller 1 101P1150 101P1150 7 Diffuser 1 101P0710 101P0710 8 O Ring 1 111P0490 111P0490 9 Venturi 1 101P0740 101P0740 10 O Ring 1 111P0560 111P0560 11 Nozzle 1 101P0720...

Страница 9: ...496SRS Key Part No 19 Gallon 35 Gallon No Description Used Tank Tank 1 Bladder Vinyl 1 U20 13 U20 9 2 Cover Flange 1 U31 446P U31 446P 3 Flange Nut 3 U36 202BT U36 202BT 4 Air Valve with Cap 1 U212 16...

Страница 10: ...ts at PENTAIR WATER s choice Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty service through the installing dealer as soon as a problem is disc...

Страница 11: ...funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 262 728 5551 2006 RPX797 Rev 2 13 06 MANUAL DEL USUARIO Sistema de bomba de agua para el hogar Modelos 500T0800 y 500T1000 293 Wright...

Страница 12: ...os visitantes a una distancia segura de las reas de trabajo El cuerpo de la bomba puede explotar si se utiliza como bomba de sobrepresi n a menos que se instale una v lvula de desahogo que sea capaz d...

Страница 13: ...ta l nea no debe tener fugas y debe ser del mismo tama o o m s grande que el tama o de la entrada de la bomba 3 Instale una v lvula de cierre en la l nea de aspiraci n del tinaco Esto permitir el mant...

Страница 14: ...i n de aire Esto debe ajustarse cuando se instala por primera vez y luego revisarse peri dicamente El interruptor de presi n est preestablecido a 2 3 4 bar 30 50 PSI La presi n de carga previa del tan...

Страница 15: ...ne en funcionamiento abra un grifo para drenar el agua del tanque de presi n 4 Observe el indicador de la presi n y verifique a qu pre si n se pone en funcionamiento la bomba 5 Cierre el grifo 6 Obser...

Страница 16: ...se deber detener NOTA Inspeccione el sistema haci ndolo marchar por un ciclo completo de bombeo para verificar su funcionamien to Para hacerlo abra un grifo y descargue la presi n hasta que la bomba s...

Страница 17: ...ocasionando una fricci n excesiva El tama o de la tuber a es muy peque o Punto filtrante obstruido Se necesitar un chorro para pozos profundos si la profundidad de su pozo es mayor que 16 pies 5 m al...

Страница 18: ...7 Difusor 1 101P0710 101P0710 8 Anillo o 1 111P0490 111P0490 9 Venturi 1 101P0740 101P0740 10 Anillo o 1 111P0560 111P0560 11 Boquilla 1 101P0720 101P0720 12 Anillo o 1 111P0480 111P0480 13 Rolanda 4...

Страница 19: ...ue de tanque de N de la Parte Cant 20 galones 30 galones 1 cisterna 1 U20 13 U20 9 2 reborde de la cubierta 1 U31 446P U31 446P 3 tuerca del reborde 3 U36 202BT U36 202BT 4 v lvula de aire con tap n 1...

Страница 20: ...ar los pro ductos defectuosos a juicio de PENTAIR WATER El comprador acepta pagar todos los cargos de mano de obra y de env o asociados a esta garant a y solicitar el servicio bajo garant a a trav s d...

Отзывы: