Linea Rotobomba 500T0800 Скачать руководство пользователя страница 8

Repair Parts

8

®

1

2

3

4

5

18

6

7

9

8

10

11

12

13

14

15

16

17

17

20

19

5155 1005

Gauge
Order separately
Part No. ZA005170

Key

Part

No.

500T0800 500T1000

No.

Description

Used

3/4 HP

1 HP

1

O-Ring, Condenser Cover

1

111P1350

111P1350

2

Condenser

1

171P5430

171P5750

3

Splash Guard

1

102P0540

102P0540

4

Intermediate Support

1

731S1540

731S1540

5

Mechanical Seal, Stationary

1

111P0510

111P0510

6

Impeller

1

101P1150

101P1150

7

Diffuser

1

101P0710

101P0710

8

O-Ring

1

111P0490

111P0490

9

Venturi

1

101P0740

101P0740

10

O-Ring

1

111P0560

111P0560

11

Nozzle

1

101P0720

101P0720

12

O-Ring

1

111P0480

111P0480

13

Washer

4

121P0810

121P0810

14

Drain Plug

4

171P1180

171P1180

15

Pump Body

1

731S1520

731S1520

16

Screw, Pump Body

4

121P1090

121P1090

17

90° Hose Barb

2

U111-212T

U111-212T

18

Tubing, Pressure Switch

1

U37-669P

U37-669P

19

Pressure Switch

1

U217-1202

U217-1202

20

Connector, 1/2" NSPM

1

J43-13C

J43-13C

Repair Parts - Pump

Содержание Rotobomba 500T0800

Страница 1: ...er operating installation or maintenance assistance Call 1 262 728 5551 2006 RPX797 Rev 4 4 06 OWNER S MANUAL Household Water Pump System Models 500T0800 and 500T1000 293 Wright St Delavan WI 53115 Ph...

Страница 2: ...uttered and properly lighted store properly all unused tools and equipment Keep visitors at a safe distance from the work areas Pump body may explode if used as a boost er pump unless relief valve cap...

Страница 3: ...the tinaco to the inlet of the pump This line must be without leaks and the same size or larger than the pump inlet size 3 Install a shut off valve in the suction line from the tinaco This will allow...

Страница 4: ...own Either wire can connect to either terminal 4 Attach the pressure switch cover Checking Tank Pressure The pressure tank is pre charged with air pressure This must be adjusted when first installed a...

Страница 5: ...Apply power 3 If the pump does not start up open a faucet to drain water from the pressure tank 4 Watch the pressure gauge and note at what pressure the pump starts 5 Close the faucet 6 Watch the pres...

Страница 6: ...he system by running it through one complete pumping cycle to make sure it works To do this open a faucet and bleed off pressure until the pump starts Close the faucet and when the pressure in the sys...

Страница 7: ...be needed over 16 5M to water setup to deliver water to deliver water Pump does not Water level in well is lower than A deep well jet will be needed if your well is more than 16 5M deliver water to fu...

Страница 8: ...tionary 1 111P0510 111P0510 6 Impeller 1 101P1150 101P1150 7 Diffuser 1 101P0710 101P0710 8 O Ring 1 111P0490 111P0490 9 Venturi 1 101P0740 101P0740 10 O Ring 1 111P0560 111P0560 11 Nozzle 1 101P0720...

Страница 9: ...496SRS Key Part No 19 Gallon 35 Gallon No Description Used Tank Tank 1 Bladder Vinyl 1 U20 13 U20 9 2 Cover Flange 1 U31 446P U31 446P 3 Flange Nut 3 U36 202BT U36 202BT 4 Air Valve with Cap 1 U212 16...

Страница 10: ...ts at PENTAIR WATER s choice Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty service through the installing dealer as soon as a problem is disc...

Страница 11: ...funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 262 728 5551 2006 RPX797 Rev 2 13 06 MANUAL DEL USUARIO Sistema de bomba de agua para el hogar Modelos 500T0800 y 500T1000 293 Wright...

Страница 12: ...os visitantes a una distancia segura de las reas de trabajo El cuerpo de la bomba puede explotar si se utiliza como bomba de sobrepresi n a menos que se instale una v lvula de desahogo que sea capaz d...

Страница 13: ...ta l nea no debe tener fugas y debe ser del mismo tama o o m s grande que el tama o de la entrada de la bomba 3 Instale una v lvula de cierre en la l nea de aspiraci n del tinaco Esto permitir el mant...

Страница 14: ...i n de aire Esto debe ajustarse cuando se instala por primera vez y luego revisarse peri dicamente El interruptor de presi n est preestablecido a 2 3 4 bar 30 50 PSI La presi n de carga previa del tan...

Страница 15: ...ne en funcionamiento abra un grifo para drenar el agua del tanque de presi n 4 Observe el indicador de la presi n y verifique a qu pre si n se pone en funcionamiento la bomba 5 Cierre el grifo 6 Obser...

Страница 16: ...se deber detener NOTA Inspeccione el sistema haci ndolo marchar por un ciclo completo de bombeo para verificar su funcionamien to Para hacerlo abra un grifo y descargue la presi n hasta que la bomba s...

Страница 17: ...ocasionando una fricci n excesiva El tama o de la tuber a es muy peque o Punto filtrante obstruido Se necesitar un chorro para pozos profundos si la profundidad de su pozo es mayor que 16 pies 5 m al...

Страница 18: ...7 Difusor 1 101P0710 101P0710 8 Anillo o 1 111P0490 111P0490 9 Venturi 1 101P0740 101P0740 10 Anillo o 1 111P0560 111P0560 11 Boquilla 1 101P0720 101P0720 12 Anillo o 1 111P0480 111P0480 13 Rolanda 4...

Страница 19: ...ue de tanque de N de la Parte Cant 20 galones 30 galones 1 cisterna 1 U20 13 U20 9 2 reborde de la cubierta 1 U31 446P U31 446P 3 tuerca del reborde 3 U36 202BT U36 202BT 4 v lvula de aire con tap n 1...

Страница 20: ...ar los pro ductos defectuosos a juicio de PENTAIR WATER El comprador acepta pagar todos los cargos de mano de obra y de env o asociados a esta garant a y solicitar el servicio bajo garant a a trav s d...

Отзывы: