LINDR KCH 01584 Скачать руководство пользователя страница 7

 

 

ˇ

 

7

 

  

WARNING:

  When  unplugging 

the  device  from  the  socket,  grab 

the  plug  and  pull  it  out.  Do  not  under 
any  circumstances  pull  at  the  cable; 
risk of damage. 

WARNING:

 To turn the  device off 

completely,  unplug  the  appliance  from 
the power socket. 

WARNING:

  In  the  event  the 

electrical 

wiring 

of 

the 

product 

becomes  damaged,  summon  a  trained 
service  technician.  Do  not  under  any 
circumstances 

repair 

the 

device 

yourself. 

WARNING:  The  cooling  system 

contains  flammable  coolant  R290 
(propane)!

 

 

 

 

WARNING:

 

Emergency 

maintenance  and  repair  of  the  cooling 
system  must  be  done  by  trained, 
authorised  technicians  familiar  with 
cooling  and  electrical  systems.  The 
technicians 

should 

have 

special 

training  and  qualification  for  handling 
flammable  substances  in  order  to 
perform 

service 

on 

coolers 

containing 

R290

Follow 

basic 

regulations 

and 

safety 

measures 

regarding service and repair! 

 WARNING:

    Do  not  use  open 

flame  or  potential  sources  of  sparks  in 
the  vicinity  of  a  cooler  using  R290 
coolant! 

 

WARNING:

 

After 

unpacking, 

place  the  cooler  so  that  heat  created 
by  the  cooling  unit  can  be  vented 
sufficiently. 

WARNING:

  Do  not  place  objects 

that could prevent air circulation on top 
of the cooler. 

5.  Installation and Placement 

Place the cooler on a horizontally level, 
stable surface (maximum permitted 
inclination of 2°). The device requires 
sufficient free space around it to allow 
air circulation. 

Ensure sufficient space for air 
circulation and heat dissipation. 

Ensure sufficient access to 
fresh air. 

The device must not be placed 
in an enclosed space. 

The device must not be placed 
in proximity to heat sources or 
exposed to direct sunlight. 

Minimum  distance  of  vents  from  an 
obstacle 

that 

would 

prevent 

air 

circulation  is  20  cm.  In  places  where 
there  are  no  vents,  minimum  distance 
is  7  cm.  The  device  is  best  used  in  a 
cool,  well  ventilated  room.  The  device 
is  designed  for  use  at  ambient 
temperature  of  16°C  –  32°C

.

The 

device

 

MUST NOT be used or stored 

at ambient temperature lower than 0 
°C.

 The device is designed for use in a 

normal  environment,  always  indoors, 
protected 

from 

rain 

or 

sunlight.  

Climate class N.

  

 

 

Содержание KCH 01584

Страница 1: ...KCH 01584 Kontakt 40 K us Green Line INSTRUCTION MANUAL FOR LINDR CONTACT DRY COOLER ENGLISH Number 004 2019 REV01 Valid 2020 02 06...

Страница 2: ...chine This manual is an integral part of the machine It must be stored at the equipment for the life of the equipment and provided to the user whenever it is installed moved used or maintained Read th...

Страница 3: ...rage supply connection and pressurisation 15 14 Inlet and outlet marking 17 15 Keg tapping and untapping 18 16 Putting into operation 24 17 Thermostat placement 25 18 Temperature and adjustment 25 19...

Страница 4: ...G Not following instructions may cause injury or damage the device WARNING Risk of injury by electrical current NOTE This symbol indicates information and recommendations for users WARNING The cooling...

Страница 5: ...ock with high energy capacity is ready to dispense well cooled beer within 5 10 minutes after turning on the device If the thermostat is set to max the thermal block can accumulate a large amount of e...

Страница 6: ...aging material out of reach of children comes with a plastic bag suffocation hazard WARNING Cleaning and maintenance of the appliance on the part of the user must not be done by unsupervised children...

Страница 7: ...f a cooler using R290 coolant WARNING After unpacking place the cooler so that heat created by the cooling unit can be vented sufficiently WARNING Do not place objects that could prevent air circulati...

Страница 8: ...tions of the Czech Republic or in accordance with the trade agreement During the validity period of the warranty we will remove any defects on the product free of charge provided these defects were no...

Страница 9: ...he Cooler Kontakt 40 K us Green Line 1 Cooler handle 7 Air compressor switch 2 Tap 8 Air outlet 5 16 speed fitting 3 Thermostat 9 Beverage outlet 3 8 speed fitting 4 Drip tray 10 Product label 5 Conde...

Страница 10: ...10 10 Package Contents The package contains 1 Tap 2 Tap wrench 3 Drip tray and sieve...

Страница 11: ...11 11 Tap Installation Fit the tap perpendicularly onto the spline coupler Secure with a flare nut and turn to the left loosen to the right Tighten with the enclosed wrench...

Страница 12: ...12 1 Outlet for keg pressurisation Connection variant with bushing hose is fitted onto the bushing and affixed with a clip Connection variant with rapid coupling Screw an F 5 8 x 5 16 8 mm rapid coup...

Страница 13: ...13 WARNING Before you screw the rapid coupling onto the 5 8 thread make sure the keg coupler air inlet for delivery medium has a non return valve fitted on it...

Страница 14: ...14 12 2 Outlet for beverage Screw an F 5 8 x 3 8 9 5 mm speed fitting onto the keg coupler...

Страница 15: ...ing device to the keg coupler by plugging a 5 16 air hose into the rapid coupling located on the rear of the cooler marked air To connect two kegs use a 5 16 Y speed fitting Plug the 3 8 beverage hose...

Страница 16: ...16...

Страница 17: ...17 14 Inlet and Outlet Marking Tap outlet 1 Tap outlet 2...

Страница 18: ...18 15 Keg Tapping and Untapping WARNING Make sure the adapter is clean before tapping the keg S system keg coupler Procedure for tapping and untapping a keg with an S system keg coupler 1 Keg tapping...

Страница 19: ...19...

Страница 20: ...20 2 Keg untapping...

Страница 21: ...21 A system keg coupler...

Страница 22: ...22 Procedure for tapping and untapping a keg with an A system keg coupler 1 Keg tapping...

Страница 23: ...23 2 Keg untapping...

Страница 24: ...ons are sufficiently tightened WARNING If leakage is found untap the keg according to point 15 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are...

Страница 25: ...f the cooled beverage is controlled by a mechanical thermostat in temperature range of 2 C to 8 C The thermostat has a numerical scale of 1 7 0 off WARNING If you are using the cooler to cool non alco...

Страница 26: ...n in air 20 How to Work with speed fittings Rapid Coupling Installation Grasp the rapid coupling and insert the hose all the way inside the rapid coupling body ca 20 mm The end of the hose must be str...

Страница 27: ...e point of sale 22 Maintenance Flush the beverage tubing of the cooler after each use with pressurised water see Sanitation by Water To make flushing easier use a sanitation adapter according to your...

Страница 28: ...at the device is not exposed to radiant heat 1x a week check that air circulation is not obstructed 1x a month check the cooling unit s condenser and clean it regularly 1x a year have an engineering i...

Страница 29: ...ation adapter is not included Can be purchased as an accessory for the cooler Sanitation procedure Once you have finished a keg connect the keg coupler to the sanitation adapter the same way as if you...

Страница 30: ...30...

Страница 31: ...r environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg air compressor does not switch on press the switch on the cooler by the device K pro...

Страница 32: ...ponents not recommended by the manufacturer 28 Spare Parts When ordering spare parts always provide the following type of product production year product s serial number full name of the spare part an...

Страница 33: ...33 30 Wiring Diagram...

Страница 34: ...34 31 Cooling Diagram...

Страница 35: ...35...

Страница 36: ...36...

Отзывы: