LINDR KCH 01584 Скачать руководство пользователя страница 27

 

 

ˇ

 

27

 

21. Environmental Protection 

 

Waste Sorting 

This product must not be disposed of in communal waste. Electrical waste in 
the 

Czech  Republic 

is 

disposed 

of 

within 

the 

Rema 

System 

(www.remasystem.cz), tel.: +420 225 988 001(002).  

In  countries  other  than  the  Czech  Republic,  waste  sorting  is  subject  to  local 
regulations 

Sorted  waste  enables  recycling  and  reusing  used  products  and  packaging 
materials.  Reuse  of  recycled  material  helps  protect  the  environment  from 

pollution  and  reduces  resource  consumption.  Local  regulations  may  regulate  the 
method of disposing household appliances at local collection points or at the point of 
sale. 

22. Maintenance 

Flush  the beverage tubing  of the cooler after  each use with pressurised water (see 
Sanitation by Water). To make flushing easier, use a sanitation adapter according to 
your type of keg coupler (not included in standard accessories). The cooler must be 
sanitised  once  every  14  days  by  a  person  with chemical  engineering  qualifications. 
The condenser must be checked for cleanliness every month. Any dirt found must be 
cleaned  with  compressed  air  or  wiped  off.  Otherwise,  there  is  a  risk  of  reduced 
cooling output or damaging of the cooler. 

 

23. Inspection before Every Use 

1.

 

Visual check.  

2.

 

Lead-in cable check. 

3.

 

Condenser cleanliness check (in case of excess pollution of the 
condenser, clean more frequently than 1x a month). 

 

WARNING

: Do not use the device if defects or malfunctions are found.

 

Содержание KCH 01584

Страница 1: ...KCH 01584 Kontakt 40 K us Green Line INSTRUCTION MANUAL FOR LINDR CONTACT DRY COOLER ENGLISH Number 004 2019 REV01 Valid 2020 02 06...

Страница 2: ...chine This manual is an integral part of the machine It must be stored at the equipment for the life of the equipment and provided to the user whenever it is installed moved used or maintained Read th...

Страница 3: ...rage supply connection and pressurisation 15 14 Inlet and outlet marking 17 15 Keg tapping and untapping 18 16 Putting into operation 24 17 Thermostat placement 25 18 Temperature and adjustment 25 19...

Страница 4: ...G Not following instructions may cause injury or damage the device WARNING Risk of injury by electrical current NOTE This symbol indicates information and recommendations for users WARNING The cooling...

Страница 5: ...ock with high energy capacity is ready to dispense well cooled beer within 5 10 minutes after turning on the device If the thermostat is set to max the thermal block can accumulate a large amount of e...

Страница 6: ...aging material out of reach of children comes with a plastic bag suffocation hazard WARNING Cleaning and maintenance of the appliance on the part of the user must not be done by unsupervised children...

Страница 7: ...f a cooler using R290 coolant WARNING After unpacking place the cooler so that heat created by the cooling unit can be vented sufficiently WARNING Do not place objects that could prevent air circulati...

Страница 8: ...tions of the Czech Republic or in accordance with the trade agreement During the validity period of the warranty we will remove any defects on the product free of charge provided these defects were no...

Страница 9: ...he Cooler Kontakt 40 K us Green Line 1 Cooler handle 7 Air compressor switch 2 Tap 8 Air outlet 5 16 speed fitting 3 Thermostat 9 Beverage outlet 3 8 speed fitting 4 Drip tray 10 Product label 5 Conde...

Страница 10: ...10 10 Package Contents The package contains 1 Tap 2 Tap wrench 3 Drip tray and sieve...

Страница 11: ...11 11 Tap Installation Fit the tap perpendicularly onto the spline coupler Secure with a flare nut and turn to the left loosen to the right Tighten with the enclosed wrench...

Страница 12: ...12 1 Outlet for keg pressurisation Connection variant with bushing hose is fitted onto the bushing and affixed with a clip Connection variant with rapid coupling Screw an F 5 8 x 5 16 8 mm rapid coup...

Страница 13: ...13 WARNING Before you screw the rapid coupling onto the 5 8 thread make sure the keg coupler air inlet for delivery medium has a non return valve fitted on it...

Страница 14: ...14 12 2 Outlet for beverage Screw an F 5 8 x 3 8 9 5 mm speed fitting onto the keg coupler...

Страница 15: ...ing device to the keg coupler by plugging a 5 16 air hose into the rapid coupling located on the rear of the cooler marked air To connect two kegs use a 5 16 Y speed fitting Plug the 3 8 beverage hose...

Страница 16: ...16...

Страница 17: ...17 14 Inlet and Outlet Marking Tap outlet 1 Tap outlet 2...

Страница 18: ...18 15 Keg Tapping and Untapping WARNING Make sure the adapter is clean before tapping the keg S system keg coupler Procedure for tapping and untapping a keg with an S system keg coupler 1 Keg tapping...

Страница 19: ...19...

Страница 20: ...20 2 Keg untapping...

Страница 21: ...21 A system keg coupler...

Страница 22: ...22 Procedure for tapping and untapping a keg with an A system keg coupler 1 Keg tapping...

Страница 23: ...23 2 Keg untapping...

Страница 24: ...ons are sufficiently tightened WARNING If leakage is found untap the keg according to point 15 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are...

Страница 25: ...f the cooled beverage is controlled by a mechanical thermostat in temperature range of 2 C to 8 C The thermostat has a numerical scale of 1 7 0 off WARNING If you are using the cooler to cool non alco...

Страница 26: ...n in air 20 How to Work with speed fittings Rapid Coupling Installation Grasp the rapid coupling and insert the hose all the way inside the rapid coupling body ca 20 mm The end of the hose must be str...

Страница 27: ...e point of sale 22 Maintenance Flush the beverage tubing of the cooler after each use with pressurised water see Sanitation by Water To make flushing easier use a sanitation adapter according to your...

Страница 28: ...at the device is not exposed to radiant heat 1x a week check that air circulation is not obstructed 1x a month check the cooling unit s condenser and clean it regularly 1x a year have an engineering i...

Страница 29: ...ation adapter is not included Can be purchased as an accessory for the cooler Sanitation procedure Once you have finished a keg connect the keg coupler to the sanitation adapter the same way as if you...

Страница 30: ...30...

Страница 31: ...r environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg air compressor does not switch on press the switch on the cooler by the device K pro...

Страница 32: ...ponents not recommended by the manufacturer 28 Spare Parts When ordering spare parts always provide the following type of product production year product s serial number full name of the spare part an...

Страница 33: ...33 30 Wiring Diagram...

Страница 34: ...34 31 Cooling Diagram...

Страница 35: ...35...

Страница 36: ...36...

Отзывы: