Left side connection (standard version)
A
C
B
D
A - Outdoor air
B - Supply air
C - Exhaust air
D - Extracted stale air
A
C
B
D
1
1. Unscrew the top cover.
2. Remove the top cover.
2
3. Position the DIP n°1 of the power board based on
the desired connection:
DIP 1 = OFF LH installation (default)
DIP 1 = ON RH installation
3
1
2
3
4
5
6
7
8
9
10
ON
DIP 1
How to change connection
For appliances not equipped with internal modulating electric
resistance
The default appliance is set in the version with
left side
connections.
To change the machine to the RIGHT side version,
proceed as follows:
A - Outdoor air
B - Supply air
C - Exhaust air
D - Extracted stale air
PLEASE NOTE:
Apply the labels, supplied with the unit,
based on the new configuration
Always disconnect power
before accessing the unit.
Lindab reserves the right to make changes without prior notice
202
2
-0
1
-
28
RHR-CF
lindab | we simplify construction
Installation instructions
12. Commissioning
The connections can be swapped to allow
for flexible installation of the appliances for
residential ventilation. The difference in the
connections regards the position of the air
connections, of the filters and of the condensate
drain and RH sensor.
Fig. 18
Fig. 19 Right side connection (supplementary version)
Fig. 20
Fig. 21
Fig. 22