Page 16 of 24
User Manual
Operation Instructions
Subject to modifications
2.1A-39002-B07
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Troubleshooting
Fault: Pump does not deliver the lubricant
Cause: Remedy:
Cartridge
empty
Â
Replace the cartridge, see page 11
Lubricant
supply
blocked
Â
Check the cartridge
No oil pressure supply
Â
Check the hydraulic system and repair it
Â
Check the tube and hose lines and replace them
Air entrapments in the suction area of the cartrigde
Â
Vent housing, see page 10 „First Instertion of cartridge“
Fault: Lubricant quantity too low
Cause: Remedy:
Throttle not adjusted correctly
Â
Turn the throttle anticlockwise by 1 to 2 notches
(more lubricant will flow out), see Fig. 3
Fault: Lubricant quantity too high
Cause: Remedy:
Throttle not adjusted correctly
Â
Turn the throttle clockwise by 1 to 2 notches
(less lubricant will flow out), see Fig. 3
Fault: Lubricant leaking at the cartridge inlet
Cause: Remedy:
Leakage
Â
Check the sealing ring in the pump unit and replace it if
necessary
Â
Check wether the cartridge is threaded correctly (hand-tight
seat)
Fault: Lubricant leaking at the grease outlet
Cause: Remedy:
Leakage
Â
Check the fittings and retighten them if necessary
Fault: Oil pressure leaking at the hydraulic system
Cause: Remedy:
Leakage
Â
Check the fittings and retighten them if necessary
Tab. 1
Troubleshooting