Maintenance
1013A94
ATTENTION!
Do not perform any maintenance or repair
work or replace the cartridge while the
hydraulic unit is in operation.
1013A94
ATTENTION!
Before beginning with maintenance or
repair work on the lubrication pump HTL
101 and before dismantling it, ensure that
the hydraulic system of the carrier is de-
pressurized.
Lubricant
Cartridge
6007b03
Fig. 7
Cartridge with Lubricant
Capacity ....................................................................... 400g
Lubricant …...………………………………..up to NLGI class 2
Chisel paste.....................................................542-34047-1
1)
EP2 grease......................................................542-34048-2
1)
1)
NOTE
The cartridges are not available as single
units. They are only supplied in packages
of 12 cartridges.
6001a02
Dispose of emptied cartridges according to
the legal regulations pertaining to envi-
ronmental protection.
Chisel paste.......................................................642-37608-1
EP2 grease........................................................642-37609-2
1 - Closure cap
2 - Cartridge
3 - Follower plate
First insertion of cartridge
6135b05
Fig. 8
Insert cartridge into the lubrication pump HTL 101
15 - Closure plug
Â
Lightly grease the inner o-ring
Â
Remove the closure cap (Fig. 7, item 1) from the cartridge
Â
Insert the cartridge in the bore hole by lightly pressing and
screw it into the housing (presented as in Fig. 8) hand-
tightly
Â
Vent housing::
- Remove closure plug (item 15, fig. 8)
- Press red follower piston (item 3, fig. 7) into the car-
tridge until lubricant comes out of the open bore hole
- Close housing with closure plug, again
Â
Operate the pump by switching on the hydraulic unit until
lubricant flows out of the opened outlet (item 3, Fig. 1)
6001a02
NOTE
The pump delivers lubricant very slowly. It
may take a while before the lubricant
flows out of the outlet without air bubbles.
Â
Connect the supply hose to the lubrication point to one of
the pump outlets (items 3 & 7, Fig. 1). Thread: G 1/4“
Â
Fill the lubricant supply hose to the lubrication point via
the lubrication hydraulic fitting by means of a manually
operated grease gun until the lubricant flows out at the lu-
brication point