D-6
MAINTENANCE
D-6
WELDER / GENERATOR MAINTENANCE
STORAGE
Store the BIG RED™ 600 in clean, dry protected areas.
CLEANING
Blow out the generator and controls periodically with low
pressure air. Do this at least once a week in particularly
dirty areas.
BRUSH REMOVAL AND REPLACEMENT
It is normal for the brushes and slip rings to wear and dark-
en slightly. Inspect the brushes when a generator overhaul
is necessary.
Do not attempt to polish slip rings while the engine is
running.
--------------------------------------------------------------------
GFCI TESTING AND RESETTING
PROCEDURE
The GFCI should be properly tested at least once
every month or whenever it is tripped. To properly
test and reset the GFCI:
• If the GFCI has tripped, first carefully remove any
load and check it for damage.
• If the equipment has been shut down, it must be
restarted.
• The equipment needs to be operating at high idle
speed and any necessary adjustments made on
the control panel so that the equipment is providing
at least 80 volts to the receptacle input terminals.
• The circuit breaker for this receptacle must not be
tripped. Reset if necessary.
• Push the "Reset" button located on the GFCI. This
will assure normal GFCI operation.
• Plug a night-light (with an "ON/OFF" switch) or
other product (such as a lamp) into the Duplex
receptacle and turn the product "ON".
• Push the "Test" button located on the GFCI. The
night-light or other product should go "OFF".
• Push the "Reset" button, again. The light or other
product should go "ON" again.
If the light or other product remains "ON" when the
"Test" button is pushed, the GFCI is not working
properly or has been incorrectly installed (miswired). If
your GFCI is not working properly, contact a quali-
fied, certified electrician who can assess the situation,
rewire the GFCI if necessary or replace the device.