TROUBLESHOOTING PROCEDURES

A.

P.C. Board Troubleshooting Procedures

Perform  the  following  checks  before  replacing  the
P.C. Board.

1. Remove  the  cover  to  the  Wire  Feed  Module

box  located  on  the  right  side  of  the  machine.
With  the  engine  running  the  green  and  red
LED  on  the  P.C.  Board  must  be  glowing.    If
not, check the following:

a)  Check  for  loose  connections  in  the  P.C.

Board plugs, pay close attention to J3.

b)  With  machine  running  at  high  idle,  check

the  following  voltages  accessible  at  P.C.
Board plug J3:

Lead Number

Voltage

610 - 600

120 + 13/-10 Volts DC

If  these  voltages  are  not  present,  check  the
wiring connections between the engine welder
and the Wire Feed Module.  If wiring is good,
then  refer  to  the  “Quick  Check  Procedure  for
Generator  Only”.    If  generator  is  operating
properly,  refer  to  “Procedure  for  Replacing
P.C. Boards”.

B.

Procedures for Replacing P.C. Boards

Before  replacing  a  P.C.  Board  which  is  suspected  of
being  defective,  visually  inspect  the  P.C.  Board  in
question  for  any  electrical or  mechanical damage  to
any of its components and conductors on the back of
the board.

1. If  there  is  no visible  damage  to  the  P.C.

Board, install a new one and see if this reme-
dies the problem.  If the problem is remedied,
reinstall the old P.C. Board to see if the prob-
lem still exists.  If it does no longer exist with
the old P.C. Board:

a)  Check  the  P.C.  Board  harness  connector

pins for corrosion, contamination, or loose-
ness.

b)  Check  leads  in  the  plug  harness  for  loose

or intermittent connection.

2. If  P.C.  Board  is  visibly  damaged  electrically,

before possibly subjecting the new P.C. Board
to the same cause of failure, check for possi-
ble shorts, opens, or grounds caused by:

a)   Frayed or pinched lead insulation.

b)   Poor  lead  termination,  such  as  a  poor

contact  or  a  short  to  adjacent  connection
or surface.

c)   Shorted  or  open  leads,  or  other  external

leads.

d)   Foreign  matter  or  interference  behind  the

P.C. Boards.

3. If P.C. Board is visibly damaged mechanically,

inspect  for  cause  then  remedy  before
installing a replacement P.C. Board.

If  there  is  damage  to  the  P.C.  Board  or  if
replacing P.C. Board corrects problem, return
it  to  the  local  Lincoln  Electric  Field  Service
Shop.

C.

Output Voltage

Constant  Voltage  Mode  --  The  open  circuit
voltage  in  CV  mode  is  7-55  volts  DC.    If  any
other  conditions  exist,  refer  to  the
Troubleshooting Chart.

D.

Procedure  for  Checking  the  Cold  Tip
Contactor (CR4)

1.   If there is no output during the initial start

up  of  the  machine,  check  to  see  if  the
“Local/Remote” switch is in “LOCAL”, if so,
switch  to  “REMOTE”  and  then  back  to
“LOCAL” and check for output voltage.  If
switch  is  in  “Remote”  switch  to  the
“LOCAL”  position  and  check  for  output
voltage.

2.   Open  side  panel  of  wire  feed  module.

With  machine  running,  verify  the  P.C.
Board is working by checking to see if the
green and red LED’s are on.  If LED’s are
not  on,  see  P.C.  Board  Troubleshooting
Procedures.    If  the  LED’s  are  on,  check
the  voltage  between  the  top  left  stud  of
the cold tip contactor (CR4) and the posi-
tive output stud.  The voltage should mea-
sure between 7 and 55 volts DC depend-
ing on the position of the CV voltage con-
trol setting.  Try adjusting the voltage con-
trol to see if this voltage changes.  If volt-
age is present, go to step 3.  If no voltage
is present, check for loose cable or wiring
connections.  If voltage is still not present,
refer to Troubleshooting Chart.

Содержание WIRE FEED MODULE 0914

Страница 1: ...stallation and thoughtful operation on your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READ ING THIS MANUAL AND THE SAFETY PRECAUTIONS CON TAINED THROUGHOUT And most importantly thin...

Страница 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Страница 3: ...ooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders...

Страница 4: ...adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent ha...

Страница 5: ...i s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan t...

Страница 6: ...mportant when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on the...

Страница 7: ...u 25 DIAGRAMS Wire Feed Module Wiring Diagram 26 Wire Feed Module Engine Welder Connection Diagram 27 Connection Diagram Classic II III IIID 300D 300G SA 250 350SA SAE 300 w WFM to LN 23P w Adapter ki...

Страница 8: ...n the gun trigger is released Simplified field installation process All control wiring connections between the welder the control panel and the WFM are easily made with in line plug type connections I...

Страница 9: ...e nance manuals supplied with your machine They include important safety precautions detailed engine starting operating and maintenance instructions and parts lists Have a qualified technician do the...

Страница 10: ...ener buttons 3 Break off upper half of machine nameplate Nameplate is scored for easy bending and break off 4 Install control panel assembly Wiring connec tions will be made later 5 Secure control pan...

Страница 11: ...Socket ratchet and small extension 10 NOTE If you are installing the WFM on the Classic I you must change the 250H thermostat to the thermostat marked 200 provided in the mounting hardware packet Mak...

Страница 12: ...ed in the mounting hardware packet Make certain the thermostat assembly does not touch the brushholder spring and the cable is clear of any moving parts Make certain the ther mostat is assembled under...

Страница 13: ...nd insulate with electrical tape 16 For Classic I III IIID 300D 300G and SA250 Codes 10889 and Below 350 SA Pipeliner 200D and 200G remove two 2 fuel tank hold down bolts on the right side of the mach...

Страница 14: ...ght side facing the control panel of the machine under the side access door On all other machines the weld out put terminals are located on the left side facing the control panel of the machine under...

Страница 15: ...output terminals The voltage should be 80 to 100 volts with the thermostat and range switch set at maxi mum NOTE OCV may be slightly higher when the unit is cold Voltmeter 25 Switch the CC CV switch t...

Страница 16: ...l panel on the welder with the mounting tab down Next mount the potentiometer and secure the knob Next mount the cv cc toggle switch with the mounting tab down Mount the amphenol and cap 5 Remove 2 sc...

Страница 17: ...around cover and tighten with the hardware removed in step 5 Keep the tightening flanges below the 3 00 position Large flat head screwdriver and pliers 11 Locate and remove 12 pin jumper plug and inst...

Страница 18: ...rminal using bolt supplied with the output terminal assembly Output panel leg attach es to the front of the machine 3 4 Socket wrench 18 Drive three 3 self tapping screws into output panel 5 16 Nut dr...

Страница 19: ...nection of the LN 7 LN 7 GMA to the Wire Feed Module Requires K584 L input cable K864 adapter and optionally the K857 for remote control See the con nection diagram in the Diagrams section a Shut the...

Страница 20: ...190 120 position for optimum welding characteristics Changing the Current Range Selector affects arc characteristics Setting the Current Range Selector one position to the right of the 190 120 positio...

Страница 21: ...it e Broken or loose connections from WFM to control panel and engine welder Refer to wiring diagram to check f Refer to P C Board Troubleshooting Procedure a In CV mode check for 10 60 VDC across pin...

Страница 22: ...feedback circuit f Faulty P C Board a Check and repair broken leads b Refer to procedure for checking Voltage Control Potentiometer on Machine c Refer to Procedure for Replacing P C Boards a Check an...

Страница 23: ...e new P C Board to the same cause of failure check for possi ble shorts opens or grounds caused by a Frayed or pinched lead insulation b Poor lead termination such as a poor contact or a short to adja...

Страница 24: ...ositive and negative output terminals replace the contactor CR3 3 If the proper voltage is not present at leads 630 631 check the wiring to CR3 coil for loose or broken connections If connections are...

Страница 25: ...P10 is available a quick check can be performed to see if the generator is operating properly Disconnect P5 and connect P10 When P10 is connected the machine will only run in Stick CC mode If generat...

Страница 26: ...T A C T O R 6 2 2 6 6 6 6 3 3 7 5 A 7 6 7 7 7 5 R 5 0 1 6 3 0 6 3 1 C V C O N T R O L 4 6 6 7 6 3 4 J 2 J 3 5 0 1 6 3 1 6 0 0 6 0 8 6 1 0 A 5 0 9 5 0 3 A 6 3 0 5 0 3 J 4 2 1 G N D 3 1 3 2 6 0 9 6 1 0...

Страница 27: ...L E W F M C O N T R O L P A N E L N E G P O S O U T P U T T E R M I N A L S C O N N E C T T O P O S N E G C O N N E C T T O N E G B R U S H H O L D E R 6 0 8 6 0 9 2 H E A V Y L E A D 8 L E A D N E G...

Страница 28: ...F E R E W I T H T H E N O R M A L M A C H I N E O P E R A T I O N C A U T I O N W H E N M O U N T I N G A D A P T E R T O W E L D E R S P E C I A L C A R E I S T O B E T A K E N A S N O T T O D A M A...

Страница 29: ...y q u a l i f i e d p e r s o n s s h o u l d i n s t a l l u s e o r s e r v i c e t h i s m a c h i n e u s i n g t h e d i s c o n n e c t s w i t c h a t t h e f u s e b o x WARNING T u r n o f f...

Страница 30: ...D O n l y q u a l i f i e d p e r s o n s s h o u l d i n s t a l l u s e o r s e r v i c e t h i s m a c h i n e u s i n g t h e d i s c o n n e c t s w i t c h a t t h e f u s e b o x WARNING T u r...

Страница 31: ...n l y q u a l i f i e d p e r s o n s s h o u l d i n s t a l l u s e o r s e r v i c e t h i s m a c h i n e u s i n g t h e d i s c o n n e c t s w i t c h a t t h e f u s e b o x WARNING T u r n o...

Страница 32: ...l y q u a l i f i e d p e r s o n s s h o u l d i n s t a l l u s e o r s e r v i c e t h i s m a c h i n e u s i n g t h e d i s c o n n e c t s w i t c h a t t h e f u s e b o x WARNING T u r n o f...

Страница 33: ...O n l y q u a l i f i e d p e r s o n s s h o u l d i n s t a l l u s e o r s e r v i c e t h i s m a c h i n e u s i n g t h e d i s c o n n e c t s w i t c h a t t h e f u s e b o x WARNING T u r n...

Страница 34: ...E O n l y q u a l i f i e d p e r s o n s s h o u l d i n s t a l l u s e o r s e r v i c e t h i s m a c h i n e u s i n g t h e d i s c o n n e c t s w i t c h a t t h e f u s e b o x WARNING T u r...

Страница 35: ...175 200 225 250 275 300 5 10 15 20 25 30 35 40 45 50 55 60 LOAD AMPS DC LOAD VOLTS DC WIRE FEEDER OCV CLASSIC I and PIPELINER 200D and 200G with WIRE FEED MODULE Reference Output Curves For Selected O...

Страница 36: ...275 300 325 350 375 400 5 10 15 20 25 30 35 40 45 50 55 60 LOAD AMPS DC LOAD VOLTS DC WIRE FEEDER OCV CLASSIC II with WIRE FEED MODULE Reference Output Curves For Selected Open Circuit Volts OCV at Wi...

Страница 37: ...275 300 325 350 375 400 5 10 15 20 25 30 35 40 45 50 55 60 LOAD AMPS DC LOAD VOLTS DC WIRE FEEDER OCV CLASSIC III and 300G with WIRE FEED MODULE Reference Output Curves For Selected Open Circuit Volts...

Страница 38: ...0890 and above with WIRE FEED MODULE Reference Output Curves For Selected Open Circuit Volts OCV at Wire Feeder 0 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 5 10 15 20 25 30 35 40...

Страница 39: ...300 325 350 375 400 5 10 15 20 25 30 35 40 45 50 55 60 LOAD AMPS DC L O A D V O L T S D C WIRE FEEDER OCV 350 SA and SA 250 CODES 10889 AND BELOW with WIRE FEED MODULE Reference Output Curves For Sele...

Страница 40: ...40 NOTES WIRE FEED MODULE...

Страница 41: ...41 NOTES WIRE FEED MODULE...

Страница 42: ...uch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo...

Страница 43: ...gute Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali ment...

Страница 44: ...s and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting P...

Отзывы: