English 12 English
welding. Connect the electrode cable to the (+) terminal
and the work clamp to the (-) terminal. Insert the
connector with the key lining up with the keyway and
rotate approximately ¼ turn clockwise. Do not over
tighten. For DC(-) welding, switch the cable connections
at the machine so that the electrode cable is connected to
(-) and the work clamp is connected to (+).
Remote Control Connection
Refer to the accessories section for a list
of remote controls. If a remote control is
used, it will be connected to the remote
connector on the front of the machine.
The machine will automatically detect the
remote control, turn on the REMOTE
LED, and switch to remote control mode. More
information on this mode of operation will be given in the
next section.
Other Controls and Features
NEW
A
: Power Switch: It turns ON/OFF the input power to the
machine.
B
: Input cable: Connect it to the mains.
C
: Fan. This machine has a F.A.N. (Fan As Needed)
circuitry inside: the fan is automatically turned ON or
OFF. This feature reduces the amount of dirt which
can be drawn inside the machine and reduces power
consumption. When the machine is turned ON the fan
will turn ON. The fan will continue to run whenever the
machine is welding. If the machine doesn’t weld for
more than five minutes, the fan will turn OFF.
D
: Water Cooler Connection SPEEDTEC 320CP work
with the water cooler COOLARC 46 (see
"Accessories" chapter).
WARNING
Read and understand the cooler manual before
connecting it to the power source.
Before connecting cooler, refer to the manual of wire
feeder.
The
COOLARC 46
is supplied by
welding power source using 9-PIN
socket.
Input voltages is 400V, 50/60Hz.
Make sure that the supply voltage of
the unit matches the cooler’s rated
voltage.
To connect the water cooler
COOLARC 46
to the power
source:
Turn off the power source and disconnect input plug.
Remove the cap from the Water Cooler Supply
Socket.
Insert 9-pin plug of the water cooler power lead into
the Water Cooler Power Supply Socket.
WARNING
Do not switch on the welding power source with the cooler
applied if the reservoir was not filled and the torch’s/gun’s
hoses are disconnected from the cooling unit. The no
observance of this warning may be cause internal
damages at the cooler unit.
Transport & Lifting
WARNING
Falling equipment can cause injury and
damage to unit.
During transportation and lifting with a crane, adhere to
the following rules:
Power source does not include the eye bolt which can
be used to transport or lifting the machine.
To lift use of suitable lifting equipment capacity.
To lifting and transport use a travers and minimum two
belts.
Lift only power source without gas cylinder, cooler and
wire feeder, or/and any other accessories.