English 8 English
Calibrate the power source
Step 1
: Turn the wire diameter switch to
position and press the
to access the
COnFIG
Setup
screen.
Step 2
: Select the
CaL
parameter with the left-hand
encoder and select
On
with the right-hand encoder.
Step 3
: Press the
on the front panel. The display
unit indicates
triGEr
.
Step 4
: Remove the torch nozzle.
Step 5
: Cut the wire.
Step 6
: Place the piece in contact with the contact tube.
Step 7
: Press the trigger.
Step 8:
The display will indicate the value of L (cable
inductance).
Step 9:
Display the value of R using the right-hand
encoder (cable resistance).
Step 10
: Exit Setup.
WARNING
When starting up for the first time, the calibration is an
unavoidable step to achieve quality welding. If polarity is
reversed, this step must be repeated
Display and use
Synergic mode
The Current, Voltage and Thickness values listed for
each wire feed speed setting are provided for
information purposes only. They correspond to
measurements under given operating conditions, such
as position, length of the end section (flat position
welding, butt welding).
The units current/voltage displayed correspond to the
average measured values, and they may differ from the
theoretical values.
Measurement indicator of displayed values :
OFF: pre-welding display of instructions.
ON: Display of measurements (average values).
Flashing: Measurements during welding.
Selection of wire, diameter, gas, welding process
Select the type of wire, the wire diameter, the used
welding gas and welding process by turning the
appropriate switch.
Selection of the material will determine the available
values for diameter, gas and processes.
If synergy does’nt exist, power source displays
nOt
SYn
,
GAS
SYn
,
DdIA
SYn
,
oR
Pro
SYn
.
Selection of welding mode, arc length and pre-
welding display
Select welding mode 2S, 4S, spot, synergic and manual
by pressing
.
Arc length can be adjusted with left
encoder (7) and pre-welding display adjustement is
performed with right encoder (8). The selection of pre-
welding preset is performed with press button
.
Manual mode
This is the disengaged mode of the welding machine.
Adjustable parameters for it are wire speed, arc
voltage and fine setting.
In this mode, only the wire speed value is displayed.
Have to select wire diameter, gas and welding
process before starting
welding.
SETUP mode
Accessing the SETUP:
The SETUP screen can only be accessed when no welding is in
progress, by setting the Wire Diameter selector on the front panel
to position 1.
It consist in two pull-down menu :
'CYCLE
’
Setting for the cycle phases. Refer to table for detail.
‘
COnFIG
’
Power source configuration
Configuring the SETUP:
In SETUP position, select
CYCLE
or
COnFIG
by pressing
.
Turn the
left-hand
encoder to scroll through the available
parameters.
Turn the
right-hand
encoder to set their value.
No welding start. All the changes are saved on exiting the