PYTHON
A-4
INSTALLATION
A-4
FRAME GROUNDING
The frame of the PYTHON must be properly ground-
ed. A ground terminal marked is mounted on the
case bottom directly behind the input power switch for
this purpose. The cable that is sent attached to the
machine is connected to this ground terminal. See the
National Electric Code for details on proper grounding
methods. Install in accordance with all local and
national electrical codes.
INPUT VOLTAGE RECONNECTION
PROCEDURE
When changing input voltages, it is necessary to
change the settings behind the access door on the
side of the machine.
Failure to do so may result in damage to the
machine.
------------------------------------------------------------------------
To reconnect the PYTHON, follow the directions as
outlined below. Follow this procedure
ONLY
while the
PYTHON is disconnected from the input power and
the capacitors have properly discharged.
1. Open the access door on the side of the machine.
2. For 200 to 230 : Position the large switch to 200-230.
For 400 to 460 : Position the large switch to 400-460.
For 550 to 575 : Position the large switch to 550-575.
3. Move the "A" lead to the appropriate terminal.
USE ON ENGINE DRIVEN POWER SUPPLIES
The PYTHON can be used on engine driven power
supplies. However, the following AC Wave Form
Voltage and Input Power Restrictions do apply.
AC Wave Form Restrictions
The PYTHON can be operated on engine driven gen-
erators as long as the engine drive output meets the
following conditions:
The AC wave form frequency is between 45 and 65
Hz.
For 200 - 230 VAC Supplies:
The AC wave form peak voltage must be below 420
volts.
The RMS voltage must be /- 15%.
* The 230 VAC auxiliaries of Lincoln engine drives
meet these conditions when run in the high idle
mode.
For 460 VAC Supplies:
The AC wave form peak voltage must be below 840
volts.
The RMS voltage of the AC wave form must be 460
VAC +/- 10%.
Input Power Restrictions
The available output current of the PYTHON may be
limited due to the output capacity of the engine driven
power supply. The following are recommended output
current settings when used with various Lincoln
engine driven power supplies.
Engine Drive
Auxiliary Power
Pro-Cut 80 Output
Cut Thickness
RANGER 8
(8KW)
30 Amps
5/16
RANGER 9
(9KW)
40 Amps
3/8
GX271
(8KW)
30 Amps
5/16
RANGER 250
(8.5KW)
35 Amps
5/16
RANGER 275
(9KW)
40 Amps
3/8
RANGER 300D
(12KW)
55 Amps
5/8
RANGER 305G
(9.5KW)
40 Amps
3/8
RANGER 305D
(9.5KW)
40 Amps
3/8
COMMANDER 300
(10KW)
45 Amps
1/2
COMMANDER 400
(10KW)
45 Amps
1/2
COMMANDER 500
(12KW)
55 Amps
5/8
VANTAGE 500
(12KW)
55 Amps
5/8