D-4
MAINTENANCE
REPLACING FILTER CARTRIDGES
Before opening door, unit must be off and the power
switch on the side of the control panel turned to the off
position.
Verify power has been switched off at the control panel, then
unlock door handle using the supplied hex tool or any standard
5/16" hex wrench.
a. Unclamp handles and lower filters.
FIGURE D.1
b. Remove filters.
FIGURE D.2
c. Install new filters.
FIGURE D.3
WARNING
1. Install new filters, making sure they are pushed
against rear of unit.
2. Reclasp filter handles to lift filters to their sealed
position.
3. Re-lock door handle using the supplied hex wrench or
any standard 5/16" hex wrench.
1. Slide filters out of unit through the door opening as
shown. See special note on next page for filter removal
on units with 4 filters deep.
2. If required by federal, state and/or local regulations and
guidelines, conceal filter cartridge in appropriate bag,
e.g. plastic bag.
3. Dispose of the filter cartridge in accordance with all
federal, state and/or local guidelines.
4. Clean the filter compartment with an industrial vacuum
cleaner that meets OSHA guidelines for Cr6 house-
keeping.
PRISM
®
Содержание Prism 4
Страница 31: ...A 23 INSTALLATION d Reclasp filter handles FIGURE A 15 PRISM ...