B-3
OPERATION
PRODUCT COMBINATIONS
PRISM WALL MOUNT (/HE) SINGLE ARM
In order to operate the Prism Wall Mount (/HE) Single Arm
system, selection of following products is required:
•
K1656-9 (1) Prism 2400 extraction fan required
•
K1655-8 (1) Prism Flexible 10 FT extraction arm; or
•
K1655-9 (1) Prism Flexible 13 FT extraction arm; or
•
K1655-12 (1) Prism Flexible 7 FT extraction arm; or
•
K1655-13 (1) Prism 13 FT Low Ceiling extraction arm; or
•
K1655-10 (1) Prism 5 FT telescopic extraction arm; or
•
K1655-14 (1) Prism 7 FT CW telescopic extraction arm required
•
K1494-2 (1) starter/overload switch for Prism 2400 fan (not
required if using optional K1669-4 Lamp Kit with Arc Sensor)
•
K1657-1 (1) Mounting Bracket (for Prism 10 FT or 13 FT
Flexible extraction arms); or
•
K1657-2 (1) Mounting Bracket (for Prism 5 FT Telescopic, 7
FT CW Telescopic, and 7 FT LC extraction arms)
PRISM WALL MOUNT DUAL ARM
In order to operate the Prism Wall Mount Dual Arm system,
selection of following products is required:
•
K1656-9 (2) Prism 2400 extraction fan required
•
K1655-8 (2) Prism Flexible 10 FT extraction arm; or
•
K1655-9 (2) Prism Flexible 13 FT extraction arm; or
•
K1655-12 (2) Prism Flexible 7 FT extraction arm; or
•
K1655-13 (2) Prism 13 FT Low Ceiling extraction arm; or
•
K1655-10 (2) Prism 5 FT telescopic extraction arm; or
•
K1655-14 (2) Prism 7 FT CW telescopic extraction arm required*
•
K1494-2 (2) starter/overload switch for Prism 2400 fan (not
required if using optional K1669-4 Lamp Kit with Arc Sensor)
•
K1657-1 (2) Mounting Bracket (for Prism 10 FT or 13 FT
Flexible extraction arms); or
•
K1657-2 (2) Mounting Bracket (for Prism 5 FT Telescopic, 7 FT
CW Telescopic, and 7 FT LC extraction arms)
*
Depending on specific application and work requirements,
various combinations of extraction arms can be used -e.g. (1)
K1655-9 Prism 10 FT Flexible arm and (1) K1655-10 Prism 5
FT Telescopic arm.
USE
Worker exposure level should be checked
upon installation and periodically
thereafter to be certain it is within
applicable federal, state and/or local
regulations and guidelines (i.e. OSHA PEL and ACGIH
TLV limits in the U.S.).
The Prism Wall Mount (/HE) is intended to be used with
Lincoln Electric extraction arm(s) and fan(s). For information on
use of these products, refer to the instruction manuals of the
corresponding arm and/or fan.
FILTER MAINTENANCE INDICATOR
The Prism Wall Mount (/HE) is provided with a Filter Maintenance
Indicator (See Figure B.1). When using the filter unit, regularly
check the Filter Maintenance Indicator when the fan is running.
The indicator slowly moves from green to red as filter cartridge
becomes saturated or clogged.
When the Filter Maintenance Indicator is red, replace the
LongLife
®
filter cartridge. See Filter Replacement for description.
The Filter Maintenance Indicator only
functions when the fan(s) is/are in operation
and the system is properly configured.
Saturation or clogging of the filter cartridge
results in a decrease of the extraction
capacity which could result in a higher
localized concentration of welding fumes.
When the Filter Maintenance Indicator is entirely red while one fan
is in operation, replace the LongLife filter cartridge. Filter
replacement is described in Maintenance Section.
WARNING
ATTENTION
WARNING
FIGURE B.1
INDICATOR
PRISM
®
WALL MOUNT