PIPEFAB™ WELDING SYSTEM
OPERATION
B-12
TIG START/END SETTINGS
FIGURE B.9
1.
Set all to Auto – Start/End se�ngs are set to “auto” by default. These se�ngs are programmed
b
ased on
p
rocess and set
p
oint to
p
rovide ideal weldi
ng
.
2. Start
T
i
m
e –
Controls the voltage for a specified �me at the beginning of the weld. During that
�me, the machine will ramp from the Start Procedure to the Welding Procedure.
3. Crater
T
i
m
e –
Controls the voltage for a specified �me
at t
h
e end o
f
t
h
e weld a
�
er t
he trigger
is released
. During the Crater �me, the machine will ramp from the Weld Procedure to the
Crater Procedure.
.
4. Current Se
�ng
s.