PIP
E
FAB™ WELDING SYSTEM
INSTALLATION
A-18
LOADING SPOOLS AND COILS
•
Keep hands, hair, clothing and tools away from rota
�
ng equipment.
•
Do not wear gloves when threading wire or changing wire spool.
•
Only quali
fi
ed personnel should install, use or service this
equipment.
1. Turn power OFF at the welding power source.
2. Squeeze the release bar on the retaining collar and remove it from the spindle.
FIGURE A.23
3. Place the spool on the spindle, aligning the spindle brake pin with one of the holes in the back side of
the spool. Be certain the wire feeds o
ff
of the spool in the proper direc
�
on.
FIGURE A.24
4. Re-install the retaining collar, with the metal bar engaging one of the grooves of the spindle. The
release bar will spring out when engaged.