Lincoln Electric INVERTEC IM526-B Скачать руководство пользователя страница 21

21

Replacement of Power Modules and Output
Diodes

Input rectifier, D13, is a power module. When mount-
ing power modules, the heat sink and module mount-
ing surface should be clean and free of burrs and for-
eign material. Apply heatsink compound (Dow 340) as
a uniform layer ideally .010” thick, to eliminate all air
pockets. This may be verified by mounting and then
removing the module. When removed, the compound
on both surfaces will appear textured as if a vacuum
had created veinlike ridges when the parts were sepa-
rated. If the compound does not have this appear-
ance, apply more heatsink compound and recheck.

Replacement of output diodes D1 thru D12 is similar.
Clean and brighten mounting surface with fine steel
wool. Compound should be used on surface between
diode and heat sink when mounting individual diodes.

The compound should be applied to the heat sink in a
very thin layer, less than 0.001 in. DO NOT apply on
diode stud and mounting nut threads.

Components must have proper torque applied to
mounting screws and to electrical terminals. Torque
the modules according to the following:

Component to Heat Sink

Terminal

Component

Torque ±10%

Torque ±10%

Switch Board

Module

44 Inch - Lbs.

(1)

N.A.

(5N - m)

Capacitor

N.A.

55 Inch - Lbs.

(6.3 N - m)

Input Rectifier

6 Inch - Lbs.

(2)

26 Inch - Lbs.

(M15454-1)

(0.7 N - m)

3 (N - m)

Output Diode

25 Inch - Lbs.

N.A.

(M15482-2)

(3 N - m)

(1)

Retorque after 3 hours to allow for spread of compound.

(2)

Tighten in staggered fashion one quarter turn at a time.

Environment Protection

High voltage connections are covered with an RTV
sealant to prevent malfunction in severe environ-
ments. Sealant must be applied to connections which
have been opened or otherwise lost their protection. A
noncorrosive electronic grade sealant such as Dow
Corning 3140, 3145, 738, Columbus Adhesives 0172
or GE RTV-162 is recommended. Sealant may also
be purchased from Lincoln Electric (order E2519
Silicone Rubber RTV Coating). Apply sealant after
machine is repaired and tested.

High voltage areas which require sealant are as listed:

- Input rectifier D13, all 5 terminals.

Printed Circuit Board Replacement

1. Handle PC Boards by edges only.

2. Store PC Boards only in the bags that disperse

static charges.

3. Inspect PC Board for burned conductors or com-

ponents. If damage is visible, inspect the machine
wiring for grounds or shorts to avoid damaging a
new PC Board.

4. If there is no visible damage to the PC Board,

install a new PC Board and see if the problem is
fixed. If the problem is fixed by the new board,
reinstall the old board and see if the problem reoc-
curs. If the problem does not reoccur, check the
wiring harness and plugs for loose connections.

Содержание INVERTEC IM526-B

Страница 1: ...ful operation on your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be...

Страница 2: ...n Make certain the insulation is large enough to cover your full area of physical contact with work and ground In addition to the normal safety precautions if welding must be performed under electrica...

Страница 3: ...fans and all other mov ing parts when starting operating or repair ing equipment 7 e In some cases it may be necessary to remove safety guards to perform required maintenance Remove guards only when...

Страница 4: ...et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan talon...

Страница 5: ...Wire Feeders to Invertec 8 10 Output Cables Plugs 10 Operating Instructions 11 13 Safety Precautions 11 Controls Description and Function 11 13 Maintenance 13 14 Capacitor Discharge Procedure 13 Routi...

Страница 6: ...e the information must be followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title pa...

Страница 7: ...from rain and snow Do not place on wet ground or in puddles ELECTRICAL INSTALLATION 1 The Invertec should be connected only by a quali fied electrician Installation should be made in accordance with t...

Страница 8: ...t terminal of polarity required by electrode Connect the work lead to the other terminal 4 Place the local remote switch in the local posi tion to allow output control at the Invertec K864 Recommended...

Страница 9: ...0 amps not 300 amps from one and 100 amps from the other This will minimize nuisance shutdown conditions In general more than two machines in parallel will not be effective due to the voltage requirem...

Страница 10: ...fication of K196 LN 9 GMA input cable with K867 universal adapter plug Output Cables Select the output cable size based upon the following chart Cable sizes for Combined Length of Electrode and Work C...

Страница 11: ...des and output current in the CC modes Control is provided over the entire output range of the power source with 1 turn of the control knob This con trol may be adjusted while under load to change pow...

Страница 12: ...rceful or driving at the maximum settings Higher spatter levels may be present at the maximum settings For CV modes this control will set the degree of pinch effect which predominantly affects short c...

Страница 13: ...position shown Hold in each position for 1 second For 575 VAC only repeat for second capacitor Repeat for the capacitor s on the other side of the machine 3 Use a DC voltmeter to check that voltage is...

Страница 14: ...r input voltage 2 Machine did not have power applied for many months 3 Machine did not produce output when power was first switched on If these circumstances apply the proper action is to switch the m...

Страница 15: ...erates OK at 230 VAC or lower No output at 380 VAC or higher Poor EXX10 stick electrode 5P performance Arc pops out No output or reduced output the first time power is applied to the machine Perform t...

Страница 16: ...5 VAC only compare voltage across 9A 13 and 13 12A then 9B 15 and 15 12B Connect as in step 3A Same voltages as above Test Result 24 VAC 0 VAC 15 VDC 0 VDC 1 VDC 5 VDC 25 VDC difference between readin...

Страница 17: ...neg 1 8 neg to 12 pos 9 pos to 4 5 neg 9 neg to 4 5 pos 1 8 pos to 9 neg 1 8 neg to 9 pos 12 pos to 4 5 neg 12 neg to 4 5 pos 12 pos to 401 403 neg 12 neg to 401 403 pos 9 pos to 402 404 neg 9 neg to...

Страница 18: ...tput plug pos to output plug neg Test Result 25 ohms 30 ohms 20 ohms 25 ohms 30 ohms 20 ohms 25 ohms 30 ohms 20 ohms 25 ohms 30 ohms 20 ohms 100 ohms 200 ohms Conclusion OK R4 open R4 shorted OK R5 op...

Страница 19: ...H1 neg 9 pos to A neg 9 pos to H5 neg 12 neg to H1 pos 12 neg to A pos 12 neg to H5 pos 9 neg to H1 pos 9 neg to A pos 9 neg to H5 pos 12 pos to H1 neg 12 pos to A neg 12 pos to H5 neg Conclusion OK...

Страница 20: ...les are lined up before making full contact with the heat sink 8 Caution The heat sink and the capacitor terminals are relatively soft material and it is very easy to cross thread the mounting screws...

Страница 21: ...Inch Lbs 6 3 N m Input Rectifier 6 Inch Lbs 2 26 Inch Lbs M15454 1 0 7 N m 3 N m Output Diode 25 Inch Lbs N A M15482 2 3 N m 1 Retorque after 3 hours to allow for spread of compound 2 Tighten in stagg...

Страница 22: ...P L U G 1 4 P I N T O P O W E R S O U R C E C A B L E R E C E P T A C L E 6 S O C K E T C A B L E R E C E P T A C L E 1 4 S O C K E T T O 1 L N 7 W I R E F E E D E R S T O 1 K 8 5 7 R E M O T E C O N...

Страница 23: ...T V I E W K 4 2 A 3 2 B G N D C 2 L 8 2 D 4 E 7 7 M 8 1 F 7 6 G 7 5 N S P A R E H 2 1 I 4 1 J 3 1 K 4 2 J 3 1 I 4 1 H 2 1 N S P A R E G 7 5 F 7 6 M 8 1 E 7 7 D 4 C 2 L 8 2 B G N D A 3 2 P I N S P A R...

Страница 24: ...LL I N V E R T E C W I T H 1 1 5 V A C S 1 9 4 0 4 1 2 1 0 9 3 A K867 PLUG TO LN 7 CONNECTION DIAGRAM N A W E L D I N G C A B L E M U S T B E S I Z E D F O R C U R R E N T A N D D U T Y C Y C L E O F...

Страница 25: ...E F D A B C 7 7 7 6 7 5 S P A R E 4 2 2 1 8 2 8 1 4 2 4 1 G N D 3 1 3 2 N D N D R E M O V E 6 P I N P L U G F R O M K 4 3 2 C A B L E I N O R D E R T O C O N N E C T K 8 6 7 P L U G L A B E L E A C H...

Страница 26: ...M P I N V E R T E C F R A M E C O N N E C T I O N N D N D F O R W I R E F E E D E R S T H A T R E T U R N A S I G N A L F O R W E L D I N G O U T P U T U S E I S O L A T I O N R E L A Y T O C L O S E...

Страница 27: ...O F A P P L I C A T I O N N B D I A G R A M S H O W S E L E C T R O D E P O S I T I V E T O C H A N G E P O L A R I T Y T U R N P O W E R O F F R E V E R S E E L E C T R O D E A N D W O R K C A B L E...

Страница 28: ...R N P O W E R O F F R E V E R S E E L E C T R O D E A N D W O R K C A B L E A T P O W E R S O U R C E E L E C T R O D E C A B L E T O L N 7 T O W O R K 1 4 P I N A M P H E N O L L N 7 C O N T R O L B...

Страница 29: ...wer source or the Amptrol or Wire Feeder to the DC Tig Starter T O P 1 4 P I N A M P H E N O L W I R E F E E D E R N B A W I R E F E E D E R C A N B E P L U G G E D I N T O T H E D C T I G S T A R T E...

Страница 30: ...L E C T R O D E P O S I T I V E T O C H A N G E P O L A R I T Y T U R N P O W E R O F F R E V E R S E E L E C T R O D E A N D W O R K C A B L E A T P O W E R S O U R C E S E T M E T E R P O L A R I T...

Страница 31: ...E V E R S E E L E C T R O D E A N D W O R K C A B L E A T P O W E R S O U R C E S E T M E T E R P O L A R I T Y S W I T C H O N R E A R O F I N V E R T E C T O C O I N C I D E W I T H P O L A R I T Y...

Страница 32: ...H1 CC CRISP CC SOFT LOCAL 275B OVERLOAD 502 TP5 250 B O T T O M 401 403 6 H6 440 A 42A R 214 12D R SWITCH H2 H3 220 H3 309 212 J 31 3 S N D FAN 311 229 THERMOSTAT H5 6 ARC FORCE 6 11 S4 5 4 ON 223A M...

Страница 33: ...L O C A L E L E C T R I C A L C O D E S 25 25W 42A 2AMP H1 6AMP 212 212 212 I C D H 42 81 42 VAC S2 MODE SWITCH R11 OUTPUT CONTROL S3 R12 S4 SWITCH SWITCH CONTROL TERMINAL THERMAL OVERLOAD INDICATOR...

Страница 34: ...INVERTEC V300 PRO V300 I NOTES...

Страница 35: ...INVERTEC V300 PRO V300 I NOTES...

Страница 36: ...INVERTEC V300 PRO V300 I NOTES...

Страница 37: ...nd ask for bulletin ED 80 or call 216 383 2259 and ask for the Welding School Registrar Lincoln Welding School BASIC COURSE 700 00 5 weeks of fundamentals There is a 10 discount on all orders of 50 00...

Страница 38: ...ch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo...

Страница 39: ...ute Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali menta...

Страница 40: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: