B-2
OPERATION
B-2
Rev. 13
INVERTEC
®
CC400-T/TP
6. DIGITAL CURRENT DISPLAY METER
Parameter will be shown accordingly in the mode of
parameter seletion, actual current output will be shown in
other mode.
7. DIGITAL VOLTAGE DISPLAY METER
Parameter will be shown accordingly in the mode of
parameter seletion, actual voltage output will ben shown
in other mode.
8. PARAMETER STORAGE
This knob is used for parameter storage.
9. PARAMETER TRANSFER
This knob is used for transfer of storage parameter.
10. PARAMETER ADJUSTMENT
This knob is used for parameters adjustment. If pulling
the Knob and adjusting at the same time, the value
changes at 10 times.
11. COOLED WATER OUTPUT TERMINAL
Connect with inlet water joint of water-cooled torch when
using water-cooled torch.
12. PROTECTIVE GAS OUTPUT TERMINAL
Connect with hose joint of TIG torch.
13.NEGATIVE OUTPUT TERMINAL
14. AMPHENOL SOCKET
This socket is used for remote control box connection.
Power source will automatically identify external controller.
Once connected with it, remote indicator will turn on and
transfer to external control status. Please see next
chapter in details.
Power Source
PIN
SIGNAL NAME
LEAD #
A
Output control pot L
77
B
Output control pot wiper
76
C
Output control pot H
75
D
Output control trigger return
2
E
Output control trigger
4
F
Ground lead ( case )
G2
15. POSITIVE OUTPUT TERMINAL
Note:
For positive polarity welding connect the electrode cable
to the positive terminal and the work cable to the negative
terminal. For negative polarity welding, reverse the
electrode and work cables.
REAR PANEL (PLEASE SEE FIGURE B.2)
.
16. INPUT BOX
This insulation box is used to cover the input connections
to provide insulation proection for operators.
This insulation box must be secure before turning on
the main power supply.
17. INPUT CABLE HOLDING BRACKET
This bracket securely holds the three phase power cables
in place.
18. GROUND CABLE CONNECTION
Connect the ground cable to the paint-free location on the
case back.
19. COOLED WATER INPUT TERMINAL
External water-cooled input connection.
20.
PROTECTIVE GAS INPUT TERMINAL
External protective gas input connection.
16
17
19
18
20
FIGURE B.2
DIP SWITCHES
INVERTEC
®
CC400-T/-TP machine offers a DIP switch
on the control board, which allows users to activate
additional features. There are 2 individual switches
integrated into this DIP switch ( Please see
FIGURE B.3
below ).
FIGURE B.3
1. DIP SWITCH 1
This switch isn
’t used for this machine.
2. DIP SWITCH 2
The DIP switch is for test mode. It should always be
OFF (down)for customers.
FAN
The fan will run without time delay once the machine
power is on.
WARNING