A-
1
INSTALLATION
A-1
Rev. 13
INVERTEC
®
CC400-T/TP
TECHNICAL SPECIFICATIONS
–
INVERTEC
®
CC400-T/TP
INPUT
– THREE PHASE ONLY
INVERTEC
®
CC400-T/TP
Standard Voltage/Phase/Frequency
380V ~ 415V(±10%)/3/50 or 60 Hz
Input Power at Rated Output ( MMA )
17KW @ 60% Duty Cycle
RATED OUTPUT
– DC ONLY
MODE
Duty Cycle
Amperes
Volts at Rated Amperes
MMA
60%
100%
400A
310A
36V
32.4V
TIG
60%
100%
400A
310A
26V
22.4V
OUTPUT
MODE
Welding Current Range
Open Circuit Voltage
Welding Voltage Range
MMA
10A ~ 400A
68V @380V Input
73V @415V Input
20.4 V ~ 36V
TIG
5A ~ 400A
68V @380V Input
73V @415V Input
10.2 V ~ 26V
RECOMMENDED INPUT WIRE AND FUSE SIZES
INVERTEC
®
CC400-T/TP
Input
Voltage/
Frequency
(Hz)
380/415V
Maximum
Input
Ampere
30/28A
Maximum
Effective
Supply
Current
23/22A
60°C Copper
Wire in
Conduct
Sizes
6mm
2
Fuse or
Breaker Size
(Super Lag)
40A
Grounding
Conductor
Size
4mm
2
PHYSICAL DIMENSIONS
INVERTEC
®
CC400-T/TP
Height
480mm
Width
350mm
Depth
730mm
Weight
34Kg
Temperature Range
Operating Temperature Range
-10°C ~ +40°C
Storage Temperature Range
-25°C ~ +55°C
For any maintenance or repair operation it is recommended to contact the nearest technical service center or directly
consult the machine division of the Shanghai Lincoln Electric. Maintenance or repairs performed by unauthorized service
center or personnel will void the menu
facturer’s warranty.